Opening Injection Pressure Consistently Detects Needle–Nerve Contact during Ultrasound-guided Interscalene Brachial Plexus Block

Author:

Gadsden Jeff C.1,Choi Jason J.1,Lin Emily1,Robinson Allegra1

Affiliation:

1. From the Department of Anesthesiology, St. Luke’s-Roosevelt Hospital Center, New York, New York (J.C.G. and A.R.); Department of Anesthesiology, Kaiser Permanente Santa Clara Medical Center, Santa Clara, California (J.J.C.); and Department of Anesthesiology, Bronx-Lebanon Hospital Center, Bronx, New York (E.L.)

Abstract

Abstract Background: Needle trauma may cause neuropathy after nerve blockade. Even without injection, nerve injury can result from forceful needle–nerve contact (NNC). High opening injection pressures (OIPs) have been associated with intrafascicular needle tip placement and nerve damage; however, the relationship between OIP and NNC is unclear. The authors conducted a prospective, observational study to define this relationship. Methods: Sixteen patients scheduled for shoulder surgery under interscalene block were enrolled if they had clear ultrasound images of the brachial plexus roots. A 22-gauge stimulating needle was inserted within 1 mm of the root, and 1-ml D5W injected at 10 ml/min by using an automated pump. OIP was monitored using an in-line pressure manometer and injections aborted if 15 psi or greater. The needle was advanced to displace the nerve slightly (NNC), and the procedure repeated. Occurrence of evoked motor response and paresthesia were recorded. Results: Fifteen patients had at least one clearly visible root. OIP at 1 mm distance from the nerve was less than 15 psi (mean peak pressure 8.2 ± 2.4 psi) and the 1-ml injection could be completed in all but two cases (3%). In contrast, OIP during NNC was 15 psi or greater (mean peak pressure 20.9 ± 3.7 psi) in 35 of 36 injections. Aborting the injection when OIP reached 15 psi prevented commencement of injection in all cases of NNC except one. Conclusion: High OIP (≥15 psi) consistently detected NNC, suggesting that injection pressure monitoring may be useful in preventing injection against nerve roots during interscalene block.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Cited by 78 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3