Compliance with Surgical Care Improvement Project for Body Temperature Management (SCIP Inf-10) Is Associated with Improved Clinical Outcomes

Author:

Scott Andrew V.1,Stonemetz Jerry L.1,Wasey Jack O.1,Johnson Daniel J.1,Rivers Richard J.1,Koch Colleen G.1,Frank Steven M.1

Affiliation:

1. From the Department of Anesthesiology/Critical Care Medicine, The Johns Hopkins Medical Institutions, Baltimore, Maryland.

Abstract

Abstract Background: In an effort to measure and improve the quality of perioperative care, the Surgical Care Improvement Project (SCIP) was introduced in 2003. The SCIP guidelines are evidence-based process measures designed to reduce preventable morbidity, but it remains to be determined whether SCIP-measure compliance is associated with improved outcomes. Methods: The authors retrospectively analyzed the electronic medical record data from 45,304 inpatients at a single institution to assess whether compliance with SCIP Inf-10 (body temperature management) was associated with a reduced incidence of morbidity and mortality. The primary outcomes were hospital-acquired infection and ischemic cardiovascular events. Secondary outcomes were mortality and hospital length of stay. Results: Body temperature on admission to the postoperative care unit was higher in the SCIP-compliant group (36.6° ± 0.5°C; n = 44,064) compared with the SCIP-noncompliant group (35.5° ± 0.5°C; n = 1,240) (P < 0.0001). SCIP compliance was associated with improved outcomes in both nonadjusted and risk-adjusted analyses. SCIP compliance was associated with a reduced incidence of hospital-acquired infection (3,312 [7.5%] vs.160 [12.9%] events; risk-adjusted odds ratio [OR], 0.68; 95% CI, 0.54 to 0.85), ischemic cardiovascular events (602 [1.4%] vs. 38 [3.1%] events; risk-adjusted OR, 0.60; 95% CI, 0.41 to 0.92), and mortality (617 [1.4%] vs. 60 [4.8%] events; risk-adjusted OR, 0.41; 95% CI, 0.29 to 0.58). Median (interquartile range) hospital length of stay was also decreased: 4 (2 to 8) versus 5 (2 to 14) days; P < 0.0001. Conclusion: Compliance with SCIP Inf-10 body temperature management guidelines during surgery is associated with improved clinical outcomes and can be used as a quality measure.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference36 articles.

1. The advantages and disadvantages of process-based measures of health care quality.;Int J Qual Health Care,2001

2. Does hospital performance on process measures directly measure high quality care or is it a marker of unmeasured care?;Health Serv Res,2008

3. The quality of health care delivered to adults in the United States.;N Engl J Med,2003

4. The holy Grail of surgical quality improvement: Process measures or risk-adjusted outcomes?;Am Surg,2006

5. Measuring the quality of surgical care: Structure, process, or outcomes?;J Am Coll Surg,2004

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3