Combined Thoracic Ultrasound Assessment during a Successful Weaning Trial Predicts Postextubation Distress

Author:

Silva Stein1,Ait Aissa Dalinda1,Cocquet Pierre1,Hoarau Lucille1,Ruiz Jean1,Ferre Fabrice1,Rousset David1,Mora Michel1,Mari Arnaud1,Fourcade Olivier1,Riu Béatrice1,Jaber Samir1,Bataille Bénoît1

Affiliation:

1. From the Critical Care Unit (S.S., D.A.A., L.H., F.F., D.R., A.M., B.R.) and Critical Care and Anaesthesiology Department (S.S., D.A.A., L.H., J.R., F.F., D.R., A.M., O.F., B.R.), University Teaching Hospital of Purpan, Toulouse, France; French National Institute of Health and Medical Research U1214, University Teaching Hospital of Purpan, Toulouse, France (S.S.); Critical Care Unit, Hopital Dieu

Abstract

Abstract Background Recent studies suggest that isolated sonographic assessment of the respiratory, cardiac, or neuromuscular functions in mechanically ventilated patients may assist in identifying patients at risk of postextubation distress. The aim of the present study was to prospectively investigate the value of an integrated thoracic ultrasound evaluation, encompassing bedside respiratory, cardiac, and diaphragm sonographic data in predicting postextubation distress. Methods Longitudinal ultrasound data from 136 patients who were extubated after passing a trial of pressure support ventilation were measured immediately after the start and at the end of this trial. In case of postextubation distress (31 of 136 patients), an additional combined ultrasound assessment was performed while the patient was still in acute respiratory failure. We applied machine-learning methods to improve the accuracy of the related predictive assessments. Results Overall, integrated thoracic ultrasound models accurately predict postextubation distress when applied to thoracic ultrasound data immediately recorded before the start and at the end of the trial of pressure support ventilation (learning sample area under the curve: start, 0.921; end, 0.951; test sample area under the curve: start, 0.972; end, 0.920). Among integrated thoracic ultrasound data, the recognition of lung interstitial edema and the increased telediastolic left ventricular pressure were the most relevant predictive factors. In addition, the use of thoracic ultrasound appeared to be highly accurate in identifying the causes of postextubation distress. Conclusions The decision to attempt extubation could be significantly assisted by an integrative, dynamic, and fully bedside ultrasonographic assessment of cardiac, lung, and diaphragm functions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Cited by 61 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3