Incidence of Intraoperative Hypersensitivity Reactions: A Registry Analysis

Author:

Saager Leif1,Turan Alparslan1,Egan Cameron1,Mascha Edward J.1,Kurz Andrea1,Bauer Maria1,Besson Hervé1,Sessler Daniel I.1,Hesler Brian D.1

Affiliation:

1. From the Department of Outcomes Research, Anesthesiology Institute (L.S., A.T., C.E., E.J.M., A.K., M.B., D.I.S., B.D.H.) and Department of Quantitative Health Sciences (E.J.M.), Cleveland Clinic, Cleveland, Ohio; and Department of Epidemiology, MSD Pharmaceutical, Oss, The Netherlands (H.B.).

Abstract

Abstract Background: Previously reported incidences for intraoperative hypersensitivity reactions vary more than 15-fold. The goal was to determine the incidence of intraoperative hypersensitivity events at a U.S. surgical center. Methods: With institutional review board (Cleveland, Ohio) approval and waiver of written/informed consent, the anesthesia records of adult patients undergoing noncardiac surgery from 2005 to 2011 at the Cleveland Clinic were queried using a novel electronic search protocol developed to identify potential hypersensitivity reactions: cardiovascular collapse defined as systolic arterial blood pressure less than 50 mmHg; administration of epinephrine; administration of diphenhydramine; physician comments in the anesthesia record suggestive of hypersensitivity reactions; laboratory tests for histamine, tryptase, or immunoglobulin-E within 24 h of surgery; and International Classification of Diseases, Ninth Revision, codes suggestive of hypersensitivity reactions. Each electronically identified candidate chart was evaluated by an adjudication committee. Hypersensitivity reactions were graded on a 5-point severity scale. From these data, the authors determined the proportion of operations having adjudicated hypersensitivity reactions, and calculated the 95% exact binomial CI. Results: Among 178,746 records, 4,008 charts were identified by the search strategies. After adjudication, 264 hypersensitivity cases were identified. The overall incidence of hypersensitivity reactions was 1:677 surgeries, corresponding to 15 (95% CI, 13 to 17) cases per 10,000 operations. The incidence of severe hypersensitivity reactions (grades 3 to 5) was 1:4,583, corresponding to 2 (95% CI, 2 to 3) cases per 10,000 operations. Conclusions: The incidence of severe hypersensitivity reactions was similar to previous reports. However, the overall incidence of hypersensitivity reactions was much greater than reported elsewhere, possibly because of a comprehensive search strategy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference43 articles.

1. De l’action anaphylactique de certains venins.;C R Soc Biol-Paris,1902

2. The ancestry of allergy: Being an account of the original experimental induction of hypersensitivity recognizing the contribution of Paul Portier.;J Allergy Clin Immunol,1985

3. Chapter 24: Anaphylaxis.;Allergy Asthma Proc,2012

4. Expanding spectrum of mast cell activation disorders: Monoclonal and idiopathic mast cell activation syndromes.;Clin Ther,2013

Cited by 29 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3