Affiliation:
1. From the Department of Anesthesiology (R.S.B., D.A.C., M.E.D., B.I.N.) and Department of Surgery (B.D.K.), University of Virginia Health System, Charlottesville, Virginia; Department of Public Health Sciences, University of Virginia, Charlottesville, Virginia (T.L.M.); and Department of Anesthesiology, University of Vermont College of Medicine, Burlington, Vermont (S.P.B.).
Abstract
Abstract
Background
The use of lung-protective ventilation (LPV) strategies may minimize iatrogenic lung injury in surgical patients. However, the identification of an ideal LPV strategy, particularly during one-lung ventilation (OLV), remains elusive. This study examines the role of ventilator management during OLV and its impact on clinical outcomes.
Methods
Data were retrospectively collected from the hospital electronic medical record and the Society of Thoracic Surgery database for subjects undergoing thoracic surgery with OLV between 2012 and 2014. Mean tidal volume (VT) during two-lung ventilation and OLV and ventilator driving pressure (ΔP) (plateau pressure − positive end-expiratory pressure [PEEP]) were analyzed for the 1,019 cases that met the inclusion criteria. Associations between ventilator parameters and clinical outcomes were examined by multivariate linear regression.
Results
After the initiation of OLV, 73.3, 43.3, 18.8, and 7.2% of patients received VT greater than 5, 6, 7, and 8 ml/kg predicted body weight, respectively. One hundred and eighty-four primary and 288 secondary outcome events were recorded. In multivariate logistic regression modeling, VT was inversely related to the incidence of respiratory complications (odds ratio, 0.837; 95% CI, 0.729 to 0.958), while ΔP predicted the development of major morbidity when modeled with VT (odds ratio, 1.034; 95% CI, 1.001 to 1.068).
Conclusions
Low VTper se (i.e., in the absence of sufficient PEEP) has not been unambiguously demonstrated to be beneficial. The authors found that a large proportion of patients continue to receive high VT during OLV and that VT was inversely related to the incidence of respiratory complications and major postoperative morbidity. While low (physiologically appropriate) VT is an important component of an LPV strategy for surgical patients during OLV, current evidence suggests that, without adequate PEEP, low VT does not prevent postoperative respiratory complications. Thus, use of physiologic VT may represent a necessary, but not independently sufficient, component of LPV.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Anesthesiology and Pain Medicine
Cited by
130 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献