Epicardial Atrial Ablation Using a Novel Articulated Robotic Medical Probe via a Percutaneous Subxiphoid Approach

Author:

Ota Takeyoshi1,Degani Amir2,Zubiate Brett2,Wolf Alon2,Choset Howie2,Schwartzman David3,Zenati Marco A.123

Affiliation:

1. Division of Cardiac Surgery, The Heart, Lung, and Esophageal Surgery Institute, University of Pittsburgh, Pittsburgh, Pennsylvania

2. Bio Robotics Lab, Carnegie Mellon University, Pittsburgh, Pennsylvania

3. Atrial Arrhythmia Center, University of Pittsburgh, Pittsburgh, Pennsylvania.

Abstract

Objective Minimally invasive epicardial atrial ablation to cure atrial fibrillation through the use of a percutaneous subxiphoid approach currently has a lack of dedicated technology for intrapericardial navigation around the beating heart. We have developed a novel articulated robotic medical probe and performed preliminary experiments in a porcine preparation. Methods In five large, healthy pigs, the teleoperated robotic system was introduced inside the pericardial space through a percutaneous subxiphoid approach. Secondary visualization of the left atrium and left atrial appendage was achieved with the use of a 5-mm scope inserted through a left thoracic port. The operator actively controlled the path of the robot by using a master manipulator. The catheter, with an irrigated radiofrequency tip, was guided through the working port of the robot to achieve epicardial ablation of the left atrium. Results Access to the pericardial space and progression around the left atrium was successful in all cases, with no interference with the beating heart such as a fatal arrhythmia, unexpected bleeding, and hypotension. Epicardial ablation was successfully performed in all five cases. No adverse hemodynamic or electrophysiological events were noted during the trials. When the animals were killed, there was no visually detected injury on the surrounding mediastinal structures caused by ablation. Transmural ablation was confirmed by histopathology of the left atrium. Conclusions We have developed a dedicated articulated robotic medical probe and successfully performed epicardial left atrial radiofrequency ablation. Based on the feedback from these preliminary experiments, the radius of curvature and proper visualization of the device are being improved in the next generation prototype.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Robotic Visible Forceps Manipulator With a Novel Linkage Bending Mechanism;Journal of Mechanisms and Robotics;2018-12-10

2. Optimal-Regularity for Serial Redundant Robots;Journal of Mechanisms and Robotics;2017-03-24

3. A survey on actuators-driven surgical robots;Sensors and Actuators A: Physical;2016-08

4. Kinematics for an Actuated Flexible n-Manifold;Journal of Mechanisms and Robotics;2015-11-24

5. A Novel, New Robotic Platform for Natural Orifice Distal Pancreatectomy;Surgical Innovation;2014-10-15