Optimized Arterial Line Artifact Identification Algorithm Cleans High-Frequency Arterial Line Data With High Accuracy in Critically Ill Patients

Author:

Khan Jasmine M.1,Maslove David M.23,Boyd J. Gordon23

Affiliation:

1. Centre for Neuroscience Studies, Queen’s University, Kingston, ON, Canada.

2. Department of Critical Care Medicine, Queen’s University, Kingston, ON, Canada.

3. Department of Medicine, Queen’s University, Kingston, ON, Canada.

Abstract

OBJECTIVES: High-frequency data streams of vital signs may be used to generate individualized hemodynamic targets for critically ill patients. Central to this precision medicine approach to resuscitation is our ability to screen these data streams for errors and artifacts. However, there is no consensus on the best method for data cleaning. Our goal was to determine whether an error-checking algorithm developed for intraoperative use could be applied to high volumes of arterial line data in an ICU population. DESIGN: Multicenter observational study. SETTING: ICUs across Ontario, Canada. PATIENTS: Nested cohort of ICU patients with shock and/or respiratory failure requiring invasive mechanical ventilation. INTERVENTIONS: High-frequency blood pressure data was analyzed. Systolic, diastolic, and mean arterial pressure minute averages were calculated. For manual analysis, a trained researcher retrospectively reviewed mean arterial pressure data, removing values that were deemed nonphysiological. The algorithm was implemented and identified artifactual data. MEASUREMENTS AND MAIN RESULTS: Arterial line data was extracted from 15 patients. A trained researcher manually reviewed 40,798 minute-by-minute data points, then subsequently analyzed them with the algorithm. Manual review resulted in the identification of 119 artifacts (0.29%). The optimized algorithm identified 116 (97%) of these artifacts. Five hundred thirty-seven data points were erroneously removed or modified. Compared with manual review, the modified algorithm incorporating absolute thresholds of greater than 30 and less than 200 mm Hg had 97.5% sensitivity, 98.7% specificity, and a Matthew correlation coefficient of 0.41. CONCLUSIONS: The error-checking algorithm had high sensitivity and specificity in detecting arterial line blood pressure artifacts compared with manual data cleaning. Given the growing use of large datasets and machine learning in critical care research, methods to validate the quality of high-frequency data is important to optimize algorithm performance and prevent spurious associations based on artifactual data.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Critical Care and Intensive Care Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3