Comparing the volume of vascular intersection of two femoral neck fracture fixation implants using an In silico technique

Author:

Putnam Matthew D.1,Rau Andrew2,Frohbergh Michael2,Ong Kevin2,Bushelow Michael1,Blauth Michael1

Affiliation:

1. DePuy Synthes, West Chester, PA; and

2. Exponent, Inc, Philadelphia, PA.

Abstract

Background: Femoral neck fracture displacement with subsequent vascular disruption is one of the factors that contribute to trauma-induced avascular necrosis of the femoral head. Iatrogenic damage of the intraosseous arterial system during fixation of femoral neck fracture is another possible cause of avascular necrosis that is less well understood. Recently, Zhao et al (2017) reconstructed 3D structures of intraosseous blood supply and identified the epiphyseal and inferior retinacular arterial system to be important structures for maintaining the femoral head blood supply after femoral neck fracture. The authors therefore recommended placing implants centrally to reduce iatrogenic vascular injuries. Our in vitro study compared the spatial footprint of a traditional dynamic hip screw with an antirotation screw versus a newly developed hip screw with an integrated antirotation screw on intraosseous vasculature. Methods: Three dimensional (3D) µCT angiograms of 9 cadaveric proximal femora were produced. Three segmented volumes—porous or cancellous bone, filled or cortical bone, and intraosseous vasculature—were converted to surface files. 3D in silico models of the fixation systems were sized and implanted in silico without visibility of the vascular maps. The volume of vasculature that overlapped with the devices was determined. The ratio of the vascular intersection to the comparator device was calculated, and the mean ratio was determined. A paired design, noninferiority test was used to compare the devices. Results: Results indicate both significant (P < 0.001) superiority and noninferiority of the hip screw with an integrated antirotation screw when compared with a dynamic hip screw and antirotation screw for the volume of vasculature that overlapped with each device in the femoral neck. Conclusions: Combining established methods of vascular visualization with newer methods enables an implant's impact on vascular intersection to be assessed in silico. This methodology suggests that when used for femoral neck fracture management, the new device intersects fewer blood vessels than the comparator. Comparative clinical studies are needed to investigate whether these findings correlate with the incidence of avascular necrosis and clinical outcomes.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3