Impact of improved upper endoscopy quality on detection of gastric precancerous lesions

Author:

Manfredi Guido1,Pedaci Marianna1,Iiritano Elena1,Alicante Saverio1,Romeo Samanta1,Bertè Roberto1,Londoni Claudio1,Menozzi Fernanda1,Brambilla Gianfranco1,Pezzilli Raffaele2,Zullo Angelo3,Buscarini Elisabetta1

Affiliation:

1. Gastroenterology and Endoscopy Department, ASST Crema ‘Maggiore’ Hospital, Crema

2. Department of Gastroenterology, San Carlo Hospital, Potenza

3. Gastroenterology and Digestive Endoscopy, ‘Nuovo Regina Margherita’ Hospital, Rome, Italy

Abstract

Objective Intestinal metaplasia (IM) is the point of no return in gastric carcinogenesis, and patients with extensive (antrum plus corpus) IM are at high risk of developing gastric cancer. We evaluated the impact of improved gastroscopy quality on the detection of gastric IM in an Italian area at high risk for gastric cancer. Methods Data of consecutive patients with gastric biopsies according to the updated Sydney System observed in 2013, 2016 and 2019 resulting in IM diagnosis were retrieved. In the first period, endoscopy was performed with standard white light instruments. In the second period, preendoscopic gastric preparation was administered, and the examinations lasting at least 7 min with standard endoscopes were performed. In the third period, the latter procedure was followed, with virtual chromoendoscopy equipped instruments. The prevalence of IM in any gastric site and that of extensive IM were compared among the three periods. Results Data of 3485 patients were available. The detection of IM in at least one gastric site increased from 29.9 to 33.6% and 34.5% (95% CI, 32.1–36.8) in the first, second and third period, respectively. The difference was statistically significant between the first and last (P = 0.02; OR, 1.24; 95% CI, 1.04–1.48) period. When considering extensive IM, the detection increased from 4.28 to 6.1% and 5.44%, although the difference failed to reach statistical significance (P = 0.076). Conclusion Our data showed that implementation of a quality protocol increased the probability to detect IM in the stomach, allowing us to select patients deserving stricter follow-up.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Gastroenterology,Hepatology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3