CARDIAC OUTPUT IN CRITICALLY ILL PATIENTS CAN BE ESTIMATED EASILY AND ACCURATELY USING THE MINUTE DISTANCE OBTAINED BY PULSED-WAVE DOPPLER

Author:

Villavicencio Christian1,Daniel Xavier1,Cartanyà Marc1,Leache Julen1,Ferré Cristina1,Roure Marina1,Bodí María2,Vives Marc3,Rodriguez Alejandro2

Affiliation:

1. Critical Care Department, Joan XXIII—University Hospital, Tarragona, Spain

2. Critical Care Department, Hospital Universitari Joan XXIII, URV/IISPV/CIBERES, Tarragona, Spain

3. Department of Anesthesiology and Critical Care, Clínica Universidad de Navarra, Universidad de Navarra, Navarra, Spain

Abstract

ABSTRACT Background: Cardiac output (CO) assessment is essential for management of patients with circulatory failure. Among the different techniques used for their assessment, pulsed-wave Doppler cardiac output (PWD-CO) has proven to be an accurate and useful tool. Despite this, assessment of PWD-CO could have some technical difficulties, especially in the measurement of left ventricular outflow tract diameter (LVOTd). The use of a parameter such as minute distance (MD) which avoids LVOTd in the PWD-CO formula could be a simple and useful way to assess the CO in critically ill patients. Therefore, the aim of this study was to evaluate the correlation and agreement between PWD-CO and MD. Methods: A prospective and observational study was conducted over 2 years in a 30-bed intensive care unit (ICU). Adult patients who required CO monitoring were included. Clinical echocardiographic data were collected within the first 24 h and at least once more during the first week of ICU stay. PWD-CO was calculated using the average value of three LVOTd and left ventricular outflow tract velocity-time integral (LVOT-VTI) measurements, and heart rate. Minute distance was obtained from the product of LVOT-VTI × heart rate. Pulsed-wave Doppler cardiac output was correlated with MD using linear regression. Cardiac output was quantified from the MD using the equation defined by linear regression. Bland-Altman analysis was also used to evaluate the level of agreement between CO calculated from MD (MD-CO) and PWD-CO. The percentage error was calculated. Results: A total of 98 patients and 167 CO measurements were analyzed. Sixty-seven (68%) were male, the median age was 66 years (interquartile range [IQR], 53–75 years), and the median Acute Physiology and Chronic Health Evaluation II score was 22 (IQR, 16–26). The most common cause of admission was shock in 81 patients (82.7%). Sixty-nine patients (70.4%) were mechanically ventilated, and 68 (70%) required vasoactive drugs. The median CO was 5.5 L/min (IQR, 4.8–6.6 L/min), and the median MD was 1,850 cm/min (IQR, 1,520–2,160 cm/min). There was a significant correlation between PWD-CO and MD-CO in the general population (R 2 = 0.7; P < 0.05). This correlation improved when left ventricular ejection fraction (LVEF) was less than 60% (R 2 = 0.85, P < 0.05). Bland-Altman analysis showed good agreement between PWD-CO and MD-CO in the general population, the median bias was 0.02 L/min, the limits of agreement were −1.92 to +1.92 L/min. The agreement was better in patients with LVEF less than 60% with a median bias of 0.005 L/min and limits of agreement of −1.56 to 1.55 L/min. The percentage error was 17% in both cases. Conclusion: Measurement of MD in critically ill patients provides a simple and accurate estimate of CO, especially in patients with reduced or preserved LVEF. This would allow earlier cardiovascular assessment in patients with circulatory failure, which is of particular interest in difficult clinical or technical conditions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Critical Care and Intensive Care Medicine,Emergency Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3