XEN Gel Stent Versus Nonpenetrating Deep Sclerectomy in Ocular Hypertension and Open Angle Glaucoma Patients

Author:

Almendral-Gómez JaimeORCID,Perucho-Martínez Susana,Martín-Giral Elena,Fernández-Escámez Carlos,Buenasmañanas-Maeso Miriam,Monja-Alarcón Natalia,Toledano-Fernández Nicolás

Abstract

Précis: XEN gel stent and nonpenetrating deep sclerectomy, both either alone or in combination with cataract surgery, significantly lowered the intraocular pressure (IOP) and reduced the number of antiglaucoma medications in patients with open angle glaucoma, with no significant differences between them. Purpose: To compare the surgical outcomes of XEN45 implant and nonpenetrating deep sclerectomy (NPDS), either alone or in combination with cataract surgery, in patients with ocular hypertension and open angle glaucoma (OAG). A retrospective and single-center cohort study was conducted on consecutive patients who underwent a XEN45 implant or an NPDS, either alone or in combination with phacoemulsification. The primary endpoint was the mean change in IOP from the baseline to the last follow-up visit. One hundred twenty-eight eyes, 65 (50.8%) eyes in the NPDS group and 63 (49.2%) eyes in the XEN group, were included in the study. The mean preoperative IOP was significantly lowered from 17.6±5.3 mm Hg and 17.8±6.2 mm Hg to 12.6±2.6 mm Hg and 13.8±2.8 mm Hg at month 12 in the XEN and NPDS groups, respectively; P<0.0001 each. At month 12, 70 (54.7%) eyes were classified as a success, with no significant differences between XEN (57.1%; 36/63 eyes) and NPDS (52.3%; 34/65 eyes) (mean difference: 4.8%; 95% CI: −30.5% to 20.8%; P=0.7115). The number of ocular hypotensive medications was significantly reduced in the XEN (from 2.1±0.7–0.2±0.5, P<0.0001) and in the NPDS (from 2.0±0.8 to 0.3±0.6, P<0.0001) groups, with no significant differences between them (P=0.2629). The incidence of postoperative adverse events in the overall study population was 12.5%, with no significant differences between groups (P=0.1275). Seven (11.1%) eyes underwent needling (XEN group) and 10 (15.4%) goniopuncture (NPDS group); P=0.4753. Conclusions: XEN45 implant and the NPDS, either alone or in combination with cataract surgery, significantly lowered IOP and reduced the number of ocular hypotensive medications in ocular hypertension and patients with open angle glaucoma.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3