“Anterior Segment Optical Coherence Tomography for Cases of High Intraocular Pressure Following XEN Implant for Glaucoma”

Author:

Tatti Filippo,Lixi Filippo,Demarinis Giuseppe,Napoli Pietro,Fossarello Maurizio

Abstract

Precis: This study showed that the XEN patency should be verified by OCT imaging in cases of encapsulated blebs. Although fibrosis plays the principal role, humour aqueous flow reduction could affect the “spacer” effect that inhibits the fibroblast attachments. Purpose: To evaluate the application of the AS-OCT imaging in studying the relationship between a low flow rate through the XEN63 and the development of a cystic bleb. Methods: Retrospective case series of three eyes presenting a cystic bleb after a XEN63 implantation for uncontrolled IOP. Demographic and clinical data were obtained from medical records. The imaging findings, complications and managements following the surgery were evaluated. Results: Three patients, with an average age of 67.3 years, initially showed a patent stent lumen and a functional bleb after surgery. The IOP of all eyes increased on average at 28.3 days from the surgery, with a mean value of 39.66 mmHg. The slit lamp examination showed a cystic bleb. The AS-OCT imaging confirmed the previous finding and revealed either a partial or total occlusion of the stent internal ostium. A Nd:YAG laser, in proximity of the ostium, was performed in order to resolve the obstruction. Although the AS-OCT imaging showed the device patency and the IOP immediately decreased, the latter became elevated again. Consequently, in all the cases a further needling procedure was needed to achieve an adequate IOP reduction. Six months after the two-step procedure, the IOP averaged 13.33 mmHg, the XEN63 lumens appeared cleared and the blebs showed a functional morphology. No adverse events were observed. Conclusion: The development of a cystic bleb may result from an altered balance between the flow-rate through the XEN63 and the fibrosis development in the postoperative healing process. A proper follow up based on slit lamp biomicroscopy, IOP measurement and AS-OCT imaging is advisable to estimate and manage a cystic bleb following XEN63 implantation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3