A Novel Visual Field Screening Program for Glaucoma With a Head-Mounted Perimeter

Author:

Arai Kota12,Nishijima Euido1,Ogawa Shumpei1ORCID,Hosaka Daisuke13,Itoh Yoshinori1,Noro Takahiko1,Okude Sachiyo1,Okada Satomi1,Yoshikawa Keiji14,Nakano Tadashi1

Affiliation:

1. Department of Ophthalmology, The Jikei University School of Medicine, Nishishimbashi

2. Department of Ophthalmology, Atsugi City Hospital, Atsugi, Kanagawa, Japan

3. Department of Ophthalmology, Machida Municipal Hospital

4. Yoshikawa Eye Clinic, Machida, Tokyo

Abstract

Précis: A novel visual field screening program with a head-mounted perimeter ‘imo’ could detect glaucoma at all stages in a short time with high accuracy. Purpose: The present study aimed to examine the accuracy and availability of a novel glaucoma visual field screening program using a head-mounted visual perimeter ‘imo.’ Participants and Methods: Eyes of 76 non-glaucoma participants and 92 glaucoma patients were examined. All patients underwent visual field tests using the Humphrey Visual Field Analyzer (30-2 or 24-2 Swedish Interactive Thresholding Algorithm standard program) and imo (the visual field screening program). We evaluated five visual field screening program indicators: sensitivity, specificity, positive predictive value, negative predictive value, and testing time. We also evaluated the ability of this visual field screening program to differentiate between glaucoma patients and normal controls using the receiver operating characteristic curves and areas under the receiver operating characteristic curves. Results: The sensitivity, specificity, positive predictive value, and negative predictive value of the visual field screening program were 76%–100%, 91%–100%, 86%–89%, and 79%–100%, respectively. The visual field screening program test time was 46±13 seconds for normal controls and 61±18, 82±21, and 105±16 econds, respectively for mild, moderate, and advanced-stage patients. The areas under the receiver operating characteristic curves were 0.77, 0.97, and 1.0 in the mild, moderate, and advanced stages, respectively. Conclusions: Visual field screening using a head-mounted perimeter ‘imo’ detected glaucoma at all stages in a short time with high accuracy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3