180- Versus 360-Degree Selective Laser Trabeculoplasty in Open Angle Glaucoma and Ocular Hypertension: A Systematic Review and Meta-Analysis

Author:

Zhu Daniel12,Shah Paras P.1,Wong Amanda3,Zhang Charles4,Barmas-Alamdari Daniel12,Bouaziz Michael12,Tirsi Andrew12,Tello Celso12

Affiliation:

1. Department of Ophthalmology, Northwell Health Eye Institute, Great Neck

2. Manhattan Eye, Ear, & Throat Hospital

3. Department of Ophthalmology, New York Eye and Ear Infirmary, New York, NY

4. Department of Ophthalmology, Ross Eye Institute, Jacobs School of Medicine and Biomedical Sciences, State University of New York, University at Buffalo, Buffalo

Abstract

Précis: This systematic review and meta-analysis found that 360-degree selective laser trabeculoplasty (SLT) is significantly more effective than 180-degree SLT at reducing intraocular pressure at 1-month and 1-year follow-ups without increased serious adverse event risk. Purpose: To determine the efficacy of 180- versus 360-degree selective laser trabeculoplasty (SLT) in adults with open angle glaucoma (OAG) and ocular hypertension (OHT). Methods: A systematic review was performed using PubMed, Embase, and Scopus databases, from 1995 to December 30, 2023, for studies comparing 180 and 360-degree SLT in adults with OAG and OHT (PROSPERO ID: CRD42024497832). Meta-analyses were performed to calculate nominal percent and raw reductions in intraocular pressure (IOP) between treatment groups at 1-month, 1-year, and 2-year follow-ups, as well as success rates, defined as a 20% or greater IOP reduction. Results: Nine studies with 1044 eyes were included; 491 received 180-degree SLT, and 553 received 360-degree SLT. At the 1-month follow-up, 360-degree SLT reduced IOP by 3.45% more (WMD=3.45; 95% CI: 2.02–4.88; P<0.00001) and 0.87 mm Hg more (WMD=0.87; 95% CI: 0.35–1.38; P=0.0010). At the 1-year follow-up, 360-degree SLT reduced IOP by 4.33% more (WMD=4.33; 95% CI: 2.35–6.32; P<0.0001) and 1.15 mm Hg more (WMD=1.15; 95% CI: 0.25–2.04; P=0.01). At 2 years of follow-up, 360-degree SLT reduced IOP by 4.86% more (WMD=4.86; 95% CI: −0.32, 10.0; P=0.07) and 1.25 mm Hg more (WMD=1.25; 95% CI: −0.29, 2.79; P=0.11); however, the difference was not statistically significant. Compared with 360-degree SLT, 180-degree SLT had a significantly lower success rate (OR=0.50; 95% CI: 0.35–0.72; P=0.0002). There was no difference in serious complications between interventions. Conclusions: 360-degree SLT is more effective than 180-degree SLT at lowering IOP at 1-month and 1-year follow-ups as well as achieving successful IOP control without increased risk of serious complications.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献