Frequency of Visual Fields Needed to Detect Glaucoma Progression: A Computer Simulation Using Linear Mixed Effects Model

Author:

Sabouri Samaneh1,Haem Elham1,Masoumpour Masoumeh2,Vermeer Koenraad A.3,Lemij Hans G.3,Yousefi Siamak45,Pourahmad Saeedeh1

Affiliation:

1. Department of Biostatistics

2. Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran

3. Rotterdam Ophthalmic Institute, the Rotterdam Eye Hospital, Rotterdam, the Netherlands

4. Department of Ophthalmology

5. Department of Genetics, Genomics, and Informatics, University of Tennessee Health Science Center, Memphis

Abstract

Précis: Irregular visual field test frequency at relatively short intervals initially and longer intervals later on in the disease provided acceptable results in detecting glaucoma progression. Purpose: It is challenging to maintain a balance between the frequency of visual field testing and the long-term costs that may result from insufficient treatment of glaucoma patients. This study aims to simulate real-world circumstances of visual field data to determine the optimum follow-up scheme for the timely detection of glaucoma progression using a linear mixed effects model (LMM). Materials and Methods: An LMM with random intercept and slope was used to simulate the series of mean deviation sensitivities over time. A cohort study including 277 glaucoma eyes that were followed for 9.0±1.2 years was used to derive residuals. Data were generated from patients with early-stage glaucoma having various regular and irregular follow-up scenarios and different rates of visual field loss. For each condition, 10,000 series of eyes were simulated, and one confirmatory test was conducted to identify progression. Results: By doing one confirmatory test, the percentage of incorrect progression detection decreased considerably. The time to detect progression was shorter for eyes with an evenly spaced 4-monthly schedule, particularly in the first 2 years. From then onward, results from twice-a-year testing were similar to results from examinations scheduled 3 times per year. Conclusions: Irregular visual field test frequency at relatively short intervals initially and longer intervals later on in the disease provided acceptable results in detecting glaucoma progression. This approach could be considered for improving glaucoma monitoring. Moreover, simulating data using LMM may provide a better estimate of the disease progression time.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3