Lack of Correlation Between Segmental Trabecular Meshwork Pigmentation and Angiographically Determined Outflow in Ex-Vivo Human Eyes

Author:

Strohmaier Clemens A.12,Wanderer Daniel1,Zhang Xiaowei1,Zhang Hao F.3,Strohmaier Susanne4,Weinreb Robert N.1,Huang Alex S.1

Affiliation:

1. Hamilton Glaucoma Center, The Viterbi Family Department of Ophthalmology, Shiley Eye Institute, University of California, San Diego, CA, USA

2. Department of Ophthalmology and Optometry, Kepler University Hospital, Johannes Kepler University, Linz, Austria

3. Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA

4. Department of Epidemiology, Center for Public Health, Medical University of Vienna, Vienna, Austria

Abstract

Precis: Trabecular meshwork pigmentation is not correlated with angiographically determined aqueous humor outflow in an ex-vivo perfusion model using human eyes. Purpose: To evaluate whether segmental trabecular meshwork (TM) pigmentation is correlated to segmental aqueous humor outflow (AHO) in human eyes. Methods: Post-mortem human eyes were acquired, and anterior segments were dissected. TM pigmentation was photographed 360-degrees around the eye. The anterior segments were then mounted onto a perfusion apparatus and perfused with DPBS until a stabile baseline outflow facility was achieved. Aqueous angiography (AHO angiography) was performed using fluorescein (2%), and segmental AHO was documented around the limbus using an angiographic camera (Spectralis HRA+OCT). Circumferential and nasal TM pigmentation were compared to respective angiographic outflow imaging using a Pearson’s correlation analysis. Results: Segmental TM pigment distribution and segmental AHO were seen. TM pigment was statistically greatest in the inferior quadrant. AHO angiographic outflow was numerically greatest in the nasal quadrant, but this was not statistically significant. No statistically significant correlation was observed (r=-0.083, P=0.06) between segmental TM pigmentation and segmental AHO angiographic signal. Analyzing just the nasal quadrant, a significant weak negative correlation was found (r=-0.296, P=0.001). Discussion: Segmental TM pigmentation circumferentially around the eye is not a good proxy for segmental AHO circumferentially around the eye and should not be used to guide trabecular minimally invasive glaucoma surgeries.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Reduced Aqueous Humor Outflow Pathway Arborization in Childhood Glaucoma Eyes;Translational Vision Science & Technology;2024-03-27

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3