Reliability of Intraocular Pressure Measurements in a Low-Contact Drive-Through Setting

Author:

Sun Lynn W.,Zhou Yunshu,Stein Joshua D.,Weizer Jennifer S.

Abstract

Précis: Drive-through intraocular pressure (IOP) measurement using iCare tonometry is a promising method of low-contact, high-throughput IOP monitoring. However, owing to its vulnerability to variable measurement technique and local air currents, the iCare may overestimate IOPs. Purpose: During the COVID-19 pandemic, a drive-through IOP measurement protocol using the iCare tonometer was established to facilitate low-contact monitoring of select glaucoma patients. As the iCare may be prone to error due to variable measurement technique and local air currents, we endeavored to assess the reliability of drive-through IOP measurements by comparing them with recent measurements taken in clinic settings. Methods: Inclusion criteria were patients with drive-through IOP measurements performed from April 28 to October 11, 2020; exclusion criteria were pre-drive-through IOPs >21 mmHg. Drive-through IOP measurements were compared with the closest previous and/or subsequent in-clinic IOP measurements. Data were gathered using the Sight Outcomes Research Collaborative (SOURCE) data repository. Results: The post-exclusion study group consisted of 314 patients receiving a total of 868 drive-through IOP measurements, all of whom had prior in-clinic measurements, and 56.8% of whom had subsequent in-clinic measurements. Drive-through IOPs were, on average, +2.4 mmHg (+14.5%; SD 4.9) higher than in-clinic IOPs. Further sub-analysis of the data showed a difference of +2.1 mmHg OD and +2.6 mmHg OS. Compared with the closest previous in-clinic visit, the difference was +2.4 mmHg OU (+2.1 mmHg OD, +2.7 mmHg OS); compared with the closest subsequent in-clinic visit, the difference was +2.3 mmHg OU (+2.1 mmHg OD, +2.5 mmHg OS). 68.6% of all drive-through IOPs were higher than corresponding in-clinic IOPs; 21.1% were lower. 25.9% of drive-through IOPs were higher by more than 5 mmHg, whereas 3.9% of drive-through IOPs were lower by more than 5 mmHg. Discussion: As teleophthalmology becomes an ever more important tool in glaucoma patient care, drive-through or walk-through IOP monitoring methods are likely to play an increasing role. However, our data reveals potential inaccuracies in drive-through iCare IOP measurements which tended to overestimate IOP. It is advisable to confirm large changes in IOP with in-clinic measurement before making management decisions. Conclusion: With better optimization of accuracy and reliability of measurements, drive-through tonometry is a promising, high-throughput, low-contact method of measuring IOP.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3