Myopia and Other Refractive Error and Their Relationships to Glaucoma Screening

Author:

Jonas Jost B.12,Jonas Rahul A.3,Jonas Shefali B.4,Panda-Jonas Songhomitra5

Affiliation:

1. Rothschild Foundation Hospital, Institut Français de Myopie, Paris, France

2. Singapore Eye Research Institute, Singapore National Eye Center, Singapore

3. Department of Ophthalmology, University of Cologne, Cologne

4. Medical University Hannover, Hannover

5. Privatpraxis Prof Jonas und Dr Panda-Jonas, Heidelberg, Germany

Abstract

Précis: A large disk, a large parapapillary delta zone and a long axial length may be used as screening criteria to detect glaucomatous optic neuropathy in highly myopic eyes. Purpose: To describe aspects for screening of glaucomatous optic neuropathy in dependence of refractive error, under special consideration of high myopia. Methods/Results: Studies on the anatomy of the myopic optic nerve head and results of investigations on the relationship between glaucomatous optic neuropathy and axial myopia were included. Conclusions: In the range from hyperopia to moderate myopia, refractive error is not a strong glaucoma risk factor and may not be included in glaucoma screening strategies. Care should be taken, that in moderate myopia, a shift of Bruch´s membrane opening usually into the temporal direction leads to parapapillary gamma zone and a corresponding shortening of the horizontal disk diameter. In these moderately myopic eyes, a secondarily small optic disk with a correspondingly small optic cup should not lead to an overlooking of intrapapillary glaucomatous changes. Prevalence of glaucomatous or glaucoma-like optic nerve atrophy (GOA) steeply increases with longer axial length in highly myopic eyes (cutoff approximately -8 diopters/axial length 26.5 mm), with prevalences higher than 50% in extremely high myopia. Besides longer axial length, morphological parameters associated with GOA in highly myopic eyes are a secondarily enlarged disk and large parapapillary delta zone. Both parameters, together with long axial length, may be used as screening criteria in high myopia for GOA. The latter is characterized by an abnormal neuroretinal rim shape, that is, vessel kinking close to the intrapapillary disk border. Factors associated with nonglaucomatous optic neuropathy are larger gamma zone and longer axial length, potentially due to an axial elongation-related retinal nerve fiber stretching.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3