Panniculus Retractor Use for Visualization of Fetal Anatomy

Author:

Wise Melissa L.,Okon Marvin,Pratt Katelyn N.,Lane Andrew S.,Carlson Laura M.,Eichelberger Kacey Y.,Crockett Amy H.,Zhang Lu,Pasko Daniel N.

Abstract

OBJECTIVE: To evaluate whether use of a panniculus retractor device for pregnant patients with body mass index (BMI) 40 or higher and a panniculus improves the completion rate of the fetal anatomic examination. METHODS: This was a randomized trial in which eligible patients with BMI 40 or higher and a panniculus were randomized to undergo their detailed fetal anatomic examination with a panniculus retractor device in place compared with usual care. The primary outcome was the completion rate of 16 prespecified views from the anatomic examination. Secondary outcomes included completion rate of all 64 views from our institution's detailed anatomic examination, duration of examination, major fetal anomaly detection rate, depth from the skin to amniotic cavity before and after retractor placement, patient and ultrasonographer satisfaction, and prespecified adverse events. We assumed a baseline completion rate of 23% for the primary outcome and targeted a twofold improvement with 80% power and two-sided α of 0.05, which resulted in a sample size of 132 participants. The goal enrollment was increased to 150 participants to account for potential dropout. Statistical tests included the Student’s t test, χ2, and relative risks (RRs) as appropriate. RESULTS: From March to July of 2023, 150 participants completed the study: 74 in the retractor group and 76 in the usual care group. Baseline characteristics were similar between groups except for panniculus grade. The completion rate of 16 prespecified views was 25.7% (19/74) in the retractor group and 31.6% (24/76) in the control group (RR 0.81, 95% CI, 0.49–1.35). There were no significant differences between groups for any of the secondary outcomes. Patient satisfaction and ultrasonographer satisfaction were similar between groups. CONCLUSION: Use of a panniculus retractor device during the fetal anatomic examination for patients with BMI 40 or higher and a panniculus was well tolerated by patients and ultrasonographers but did not improve the completion rate of 16 prespecified fetal anatomic views. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT05764408.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3