Evaluating ChatGPT on Orbital and Oculofacial Disorders: Accuracy and Readability Insights

Author:

Balas Michael1ORCID,Janic Ana1,Daigle Patrick2,Nijhawan Navdeep2,Hussain Ahsen3,Gill Harmeet2,Lahaie Gabriela L.4,Belliveau Michel J.5,Crawford Sean A.16,Arjmand Parnian7,Ing Edsel B.28ORCID

Affiliation:

1. Temerty Faculty of Medicine

2. Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada

3. Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada

4. Department of Ophthalmology, Queen’s University, Kingston, Ontario, Canada

5. Department of Ophthalmology, University of Ottawa and The Ottawa Hospital Research Institute, Ottawa, Ontario, Canada

6. Division of Vascular Surgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada

7. Mississauga Retina Institute, Toronto, Ontario, Canada; and

8. Department of Ophthalmology and Vision Sciences, University of Alberta, Edmonton, Alberta, Canada

Abstract

Purpose: To assess the accuracy and readability of responses generated by the artificial intelligence model, ChatGPT (version 4.0), to questions related to 10 essential domains of orbital and oculofacial disease. Methods: A set of 100 questions related to the diagnosis, treatment, and interpretation of orbital and oculofacial diseases was posed to ChatGPT 4.0. Responses were evaluated by a panel of 7 experts based on appropriateness and accuracy, with performance scores measured on a 7-item Likert scale. Inter-rater reliability was determined via the intraclass correlation coefficient. Results: The artificial intelligence model demonstrated accurate and consistent performance across all 10 domains of orbital and oculofacial disease, with an average appropriateness score of 5.3/6.0 (“mostly appropriate” to “completely appropriate”). Domains of cavernous sinus fistula, retrobulbar hemorrhage, and blepharospasm had the highest domain scores (average scores of 5.5 to 5.6), while the proptosis domain had the lowest (average score of 5.0/6.0). The intraclass correlation coefficient was 0.64 (95% CI: 0.52 to 0.74), reflecting moderate inter-rater reliability. The responses exhibited a high reading-level complexity, representing the comprehension levels of a college or graduate education. Conclusions: This study demonstrates the potential of ChatGPT 4.0 to provide accurate information in the field of ophthalmology, specifically orbital and oculofacial disease. However, challenges remain in ensuring accurate and comprehensive responses across all disease domains. Future improvements should focus on refining the model’s correctness and eventually expanding the scope to visual data interpretation. Our results highlight the vast potential for artificial intelligence in educational and clinical ophthalmology contexts.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology,General Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3