Semiautomated MRI-Based Method for Orbital Volume and Contour Analysis

Author:

Smadar Lital12,Arazi Mattan12,Greenberg Gahl23,Haviv Limor24,Benifla Or24,Zabatani Amit256,Fabian Ina7,Dagan Mayan8,Gutovitz Joel M.12,Ben Simon Guy J.126,Landau-Prat Daphna126

Affiliation:

1. Orbital Ophthalmic Plastic & Lacrimal Surgery Institute, Goldschleger Eye Institute, Sheba Medical Center, Tel Hashomer

2. School of Medicine, Faculty of Medical and Health Sciences, Tel Aviv University, Ramat Aviv

3. Department of Diagnostic Imaging, Section of Neuroradiology, Sheba Medical Center, Ramat Gan

4. PlanNet - The Sheba 3D Lab, Sheba Medical Center

5. Department of Orthopedics, Sheba Medical Center

6. The Sheba Talpiot Medical Leadership Program, Sheba Medical Center, Tel Hashomer

7. Department of Cell and Developmental Biology, School of Medicine, Tel Aviv University, Tel Aviv

8. Adelson school of medicine, Ariel University, Ariel, Israel

Abstract

Purpose: The architecture of the orbital cavity is intricate, and precise measurement of its growth is essential for managing ocular and orbital pathologies. Most methods for those measurements are by CT imaging, although MRI for soft tissue assessment is indicated in many cases, specifically pediatric patients. This study introduces a novel semiautomated MRI-based approach for depicting orbital shape and dimensions. Design: A retrospective cohort study. Participants: Patients with at least 1 normal orbit who underwent both CT and MRI imaging at a single center from 2015 to 2023. Methods: Orbital dimensions included volume, horizontal and vertical lengths, and depth. These were determined by manual segmentation followed by 3-dimensional image processing software. Main Outcome Measures: Differences in orbital measurements between MRI and CT scans. Results: Thirty-one patients (mean age 47.7 ± 23.8 years, 21 [67.7%]) females, were included. The mean differences in delta values between orbital measurements on CT versus MRI were: volume 0.03 ± 2.01 ml, horizontal length 0.53 ± 2.12 mm, vertical length, 0.36 ± 2.53 mm, and depth 0.97 ± 3.90 mm. The CT and. MRI orbital measurements were strongly correlated: volume (r = 0.92, p < 0.001), horizontal length (r = 0.65, p < 0.001), vertical length (r = 0.57, p = 0.001), and depth (r = 0.46, p = 0.009). The mean values of all measurements were similar on the paired-samples t test: p = 0.9 for volume (30.86 ± 5.04 ml on CT and 30.88 ± 4.92 ml on MRI), p = 0.2 for horizontal length, p = 0.4 for vertical length, and p = 0.2 for depth. Conclusions: We present an innovative semiautomated method capable of calculating orbital volume and demonstrating orbital contour by MRI validated against the gold standard CT-based measurements. This method can serve as a valuable tool for evaluating diverse orbital processes.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3