“Blue Scrub Lid Retraction”: Changes in Eyelid Position on the Day of Surgery

Author:

Ducker Laurence G.1,Halbach Caroline S.1,Piazza Amber N.2,Rajjoub Raneem D.1,Kamboj Alisha1,Harrison Andrew R.13,Mokhtarzadeh Ali1

Affiliation:

1. Department of Ophthalmology and Visual Neurosciences, University of Minnesota, Minneapolis, Minnesota, U.S.A.

2. Department of Ophthalmology and Visual Neurosciences, University of Minnesota Medical School, Minneapolis, Minnesota, U.S.A.

3. Department of Otolaryngology and Head and Neck Surgery, University of Minnesota, Minneapolis, Minnesota, U.S.A.

Abstract

Purpose: The aim of this study is to test the hypothesis that margin-reflex distance 1 (MRD1) on the day of surgery will be higher than the MRD1 measured at the in-clinic consult visit among patients undergoing blepharoptosis repair due to an increased sympathetic drive. Methods: Patients evaluated for involutional blepharoptosis repair were prospectively enrolled over a 12-month period in this single-center, self-controlled study. Three investigators independently determined MRD1 using cropped photos taken of patients at the in-clinic consult visit and on the day of surgery. A difference in height was tested for by using the 2-tailed Wilcoxon signed rank test. Results: Evaluated in this study were 76 eyelids from 38 patients. Over 3-quarters of study participants had a higher MRD1 in the right and OSs on the day of surgery than at their in-clinic consultation visit (p < 0.001). The mean increase in MRD1 for the right eyelid and left eyelid was 1.0 mm (range: 0–3.15 mm) and 1.1 mm (range: 0–2.7 mm), respectively. Conclusions: In patients with involutional blepharoptosis, we conclude that MRD1 is higher on the day of surgery as compared with the in-clinic consult visit. This may be secondary to the stress of surgery and an associated increase in sympathetic drive. In some cases, this change in eyelid position led to resolution of apparent involutional ptosis altogether. Caution should be used when considering deferral of ptosis repair on the basis of exam findings present on the day of surgery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3