Stereotactic Navigation for Placement of Pedicle Screws in the Thoracic Spine

Author:

Youkilis Andrew S.1,Quint Douglas J.1,McGillicuddy John E.1,Papadopoulos Stephen M.1

Affiliation:

1. Department of Neurosurgery and Department of Radiology, Section of Neuroradiology, University of Michigan Medical Center, Ann Arbor, Michigan

Abstract

Abstract OBJECTIVE Pedicle screw fixation in the lumbar spine has become the standard of care for various causes of spinal instability. However, because of the smaller size and more complex morphology of the thoracic pedicle, screw placement in the thoracic spine can be extremely challenging. In several published series, cortical violations have been reported in up to 50% of screws placed with standard fluoroscopic techniques. The goal of this study is to evaluate the accuracy of thoracic pedicle screw placement by use of image-guided techniques. METHODS During the past 4 years, 266 image-guided thoracic pedicle screws were placed in 65 patients at the University of Michigan Medical Center. Postoperative thin-cut computed tomographic scans were obtained in 52 of these patients who were available to enroll in the study. An impartial neuroradiologist evaluated 224 screws by use of a standardized grading scheme. All levels of the thoracic spine were included in the study. RESULTS Chart review revealed no incidence of neurological, cardiovascular, or pulmonary injury. Of the 224 screws reviewed, there were 19 cortical violations (8.5%). Eleven (4.9%) were Grade II (≤2 mm), and eight (3.6%) were Grade III (>2 mm) violations. Only five screws (2.2%), however, were thought to exhibit unintentional, structurally significant violations. Statistical analysis revealed a significantly higher rate of cortical perforation in the midthoracic spine (T4–T8, 16.7%; T1–T4, 8.8%; and T9–T12, 5.6%). CONCLUSION The low rate of cortical perforations (8.5%) and structurally significant violations (2.2%) in this retrospective series compares favorably with previously published results that used anatomic landmarks and intraoperative fluoroscopy. This study provides further evidence that stereotactic placement of pedicle screws can be performed safely and effectively at all levels of the thoracic spine.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Cited by 185 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3