Volume Replacement Therapy during Major Orthopedic Surgery Using Voluven® (Hydroxyethyl Starch 130/0.4) or Hetastarch

Author:

Gandhi Sweeta D.1,Weiskopf Richard B.2,Jungheinrich Cornelius3,Koorn Robert4,Miller Diane5,Shangraw Robert E.6,Prough Donald S.7,Baus Daniela8,Bepperling Frank9,Warltier David C.10

Affiliation:

1. Assistant Professor of Anesthesiology, Department of Anesthesiology.

2. Emeritus Professor of Anesthesiology, University of California, San Francisco, California. Dr. Weiskopf was an employee of Novo Nordisk, Bagsvaeerd, Denmark at the time of manuscript preparation.

3. Director Medical Affairs.

4. Anesthesia Associates of Southern Connecticut, Norwalk, Connecticut.

5. Professor of Anesthesiology and Perioperative Medicine, Department of Anesthesiology, Portland Veteran Affairs Medical Center, Portland, Oregon.

6. Professor of Anesthesiology and Perioperative Medicine, Department of Anesthesiology and Perioperative Medicine, Oregon Health and Science University, Portland, Oregon.

7. Professor and Chairman of Anesthesiology, Department of Anesthesiology, University of Texas Medical Branch, Galveston, Texas.

8. Clinical Project Manager.

9. Director Preclinical and Clinical Development Pharma, Fresenius Kabi, Bad Homburg, Germany.

10. Professor and Chairman of Anesthesiology and Professor of Medicine (Division of Cardiovascular Diseases) and Pharmacology and Toxicology, Department of Anesthesiology, Pharmacology and Toxicology, and Medicine (Division of Cardiovascular Diseases), Clement J. Zablocki Veterans Affairs Medical Center and the Medical College of Wisconsin, Milwaukee, Wisconsin.

Abstract

Background The purpose of this study was to test the equivalence of efficacy and compare the safety of the 6% hydroxyethyl starches (HES) Voluven (HES 130/0.4; Fresenius Kabi, Bad Homburg, Germany) and hetastarch (HES 670/0.75 in saline) for intravascular volume replacement therapy during major orthopedic surgery. Methods In a prospective, controlled, randomized, double-blind, multicenter trial of patients undergoing major orthopedic surgery, 49 patients were treated with HES 130/0.4 and 51 patients were treated with hetastarch. Infusion of colloids was guided by central venous and arterial blood pressures. The primary efficacy endpoint was the volume of colloid solution infused; the primary safety endpoints were calculated total erythrocyte loss, the nadir factor VIII activity, and the nadir von Willebrand factor concentration within 2 h of completion of surgery. Results The total volume of colloid solution required for intraoperative volume replacement did not differ between HES 130/0.4 and hetastarch (1,613+/-778 [SD] ml for HES 130/0.4 and 1,584+/-958 ml for hetastarch). The nadir factor VIII activity within 2 h of the end of surgery was lower for hetastarch than for HES 130/0.4 (P=0.0499); for those who received greater than 1,000 ml colloid, the nadir factor VIII activity and von Willebrand factor concentration within 2 h of end of surgery were lower for hetastarch than for HES 130/0.4 (P=0.0487 and P=0.008, respectively). Conclusion Voluven (HES 130/0.4) and hetastarch are equally efficacious plasma volume substitutes; however, HES 130/0.4 has a lesser effect on coagulation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference33 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3