Affiliation:
1. From the Department of Anesthesiology (D.J.K.), Department of Health Sciences Research (R.K.L., R.E.C.), and Department of Medicine, Division of Pulmonary and Critical Care Medicine (O.G.), Mayo Clinic, Rochester, Minnesota; Department of Surgery (P.K.P.) and Department of Anesthesiology (J.M.B.), University of Michigan School of Medicine, Ann Arbor, Michigan; Department of Surgery (H.L.A.), St J
Abstract
Abstract
Background:
Acute respiratory distress syndrome (ARDS) remains a serious postoperative complication. Although ARDS prevention is a priority, the inability to identify patients at risk for ARDS remains a barrier to progress. The authors tested and refined the previously reported surgical lung injury prediction (SLIP) model in a multicenter cohort of at-risk surgical patients.
Methods:
This is a secondary analysis of a multicenter, prospective cohort investigation evaluating high-risk patients undergoing surgery. Preoperative ARDS risk factors and risk modifiers were evaluated for inclusion in a parsimonious risk-prediction model. Multiple imputation and domain analysis were used to facilitate development of a refined model, designated SLIP-2. Area under the receiver operating characteristic curve and the Hosmer–Lemeshow goodness-of-fit test were used to assess model performance.
Results:
Among 1,562 at-risk patients, ARDS developed in 117 (7.5%). Nine independent predictors of ARDS were identified: sepsis, high-risk aortic vascular surgery, high-risk cardiac surgery, emergency surgery, cirrhosis, admission location other than home, increased respiratory rate (20 to 29 and ≥30 breaths/min), Fio2 greater than 35%, and Spo2 less than 95%. The original SLIP score performed poorly in this heterogeneous cohort with baseline risk factors for ARDS (area under the receiver operating characteristic curve [95% CI], 0.56 [0.50 to 0.62]). In contrast, SLIP-2 score performed well (area under the receiver operating characteristic curve [95% CI], 0.84 [0.81 to 0.88]). Internal validation indicated similar discrimination, with an area under the receiver operating characteristic curve of 0.84.
Conclusions:
In this multicenter cohort of patients at risk for ARDS, the SLIP-2 score outperformed the original SLIP score. If validated in an independent sample, this tool may help identify surgical patients at high risk for ARDS.