Myocardial Function during Low versus Intermediate Tidal Volume Ventilation in Patients without Acute Respiratory Distress Syndrome

Author:

Cherpanath Thomas G. V.1,Simonis Fabienne D.1,Bouma Berto J.1,de Bruin-Bon Rianne H.1,Determann Rogier M.1,Juffermans Nicole P.1,Gama de Abreu Marcelo1,Pelosi Paolo1,Serpa Neto Ary1,Groeneveld Johan A. B.1,Schultz Marcus J.1,Lagrand Wim K.1

Affiliation:

1. From the Departments of Intensive Care Medicine (T.G.V.C., F.D.S., N.P.J., W.K.L.) and Cardiology (B.J.B., R.H.d.B.-B.); and the Laboratory of Experimental Intensive Care and Anesthesiology (M.J.S.); Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands; the Department of Intensive Care, Onze Lieve Vrouwe Gasthuis Hospital, Amsterdam, The Netherlands (R.M.D); th

Abstract

Abstract Background Mechanical ventilation with low tidal volumes has the potential to mitigate ventilation-induced lung injury, yet the clinical effect of tidal volume size on myocardial function has not been clarified. This cross-sectional study investigated whether low tidal volume ventilation has beneficial effects on myocardial systolic and diastolic function compared to intermediate tidal volume ventilation. Methods Forty-two mechanically ventilated patients without acute respiratory distress syndrome (ARDS) underwent transthoracic echocardiography after more than 24 h of mechanical ventilation according to the Protective Ventilation in Patients without ARDS (PReVENT) trial comparing a low versus intermediate tidal volume strategy. The primary outcome was left ventricular and right ventricular myocardial performance index as measure for combined systolic and diastolic function, with lower values indicating better myocardial function and a right ventricular myocardial performance index greater than 0.54 regarded as the abnormality threshold. Secondary outcomes included specific systolic and diastolic parameters. Results One patient was excluded due to insufficient acoustic windows, leaving 21 patients receiving low tidal volumes with a tidal volume size (mean ± SD) of 6.5 ± 1.8 ml/kg predicted body weight, while 20 patients were subjected to intermediate tidal volumes receiving a tidal volume size of 9.5 ± 1.6 ml/kg predicted body weight (mean difference, −3.0 ml/kg; 95% CI, −4.1 to −2.0; P < 0.001). Right ventricular dysfunction was reduced in the low tidal volume group compared to the intermediate tidal volume group (myocardial performance index, 0.41 ± 0.13 vs. 0.64 ± 0.15; mean difference, −0.23; 95% CI, −0.32 to −0.14; P < 0.001) as was left ventricular dysfunction (myocardial performance index, 0.50 ± 0.17 vs. 0.63 ± 0.19; mean difference, −0.13; 95% CI, −0.24 to −0.01; P = 0.030). Similarly, most systolic parameters were superior in the low tidal volume group compared to the intermediate tidal volume group, yet diastolic parameters did not differ between both groups. Conclusions In patients without ARDS, intermediate tidal volume ventilation decreased left ventricular and right ventricular systolic function compared to low tidal volume ventilation, although without an effect on diastolic function. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3