Diagnosis of Insufficiency Fracture After Radiotherapy in Patients With Cervical Cancer: Contribution of Technetium Tc 99m-Labeled Methylene Diphosphonate Single-Photon Emission Computed Tomography/Computed Tomography

Author:

Zhang Linqi,He Qiao,Jiang Ming,Zhang Bing,Zhong Xi,Zhang Rusen

Abstract

BackgroundInsufficiency fractures (IFs) are a type of stress fracture caused by the effects of normal or physiological stresses on abnormally weakened bone. Frequently, these fractures are occult, and a portion of these fractures is misdiagnosed as bone metastases on a whole-body bone scan (WBS). The aim of this study was to evaluate a potential benefit of single-photon emission computed tomography/computed tomography (SPECT/CT) with metabolic and morphological imaging to diagnose IF in patients with cervical cancer after radiotherapy.MethodsThis article presents a retrospective review of 35 patients with cervical cancer after radiotherapy in patients (females; mean age, 55.94 ± 8.75 years; range, 36–73 years) who were referred to have WBS to determine whether there was any bone metastasis. The criterion standard was based on radiological investigations, clinical information, and follow-up at a minimum of 12 months.ResultsInsufficiency fractures were most frequently observed in the sacrum, accounting for 52.5% (21/40) of lesions. Fracture lines or sclerotic lines were noted in the IF lesion in 19 of 40 lesions on CT, and osteosclerosis was seen in 31 of 40 lesions. On WBS analysis, the sensitivity for detected lesions was 87.5% (42/48) for WBS. Nineteen lesions were interpreted as benign, 6 lesions were malignant, and 21 (43.8%) lesions were equivocal. Based on the criterion standard, WBS had an accuracy of only 47.9% (23/48). On SPECT/CT analysis, all of the lesions were observed on SPECT/CT; only 3 (6.25%) of 48 lesions were equivocal, and the accuracy was 89.6% (43/48).ConclusionsSingle-photon emission computed tomography/computed tomography should be included in the differential diagnoses when lesions show elevated technetium Tc 99m–labeled methylene diphosphonate uptake on WBS. Compared with a WBS alone, a more accurate diagnosis of IF can be obtained using SPECT/CT, which resulted not only in fewer equivocal lesions but also in a higher diagnostic accuracy.

Publisher

BMJ

Subject

Obstetrics and Gynecology,Oncology

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3