Sentinel Lymph Node Biopsy in Vulvar Cancer Using Combined Radioactive and Fluorescence Guidance

Author:

Verbeek Floris P.R.,Tummers Quirijn R.J.G.,Rietbergen Daphne D.D.,Peters Alexander A.W.,Schaafsma Boudewijn E.,van de Velde Cornelis J.H.,Frangioni John V.,van Leeuwen Fijs W.B.,Gaarenstroom Katja N.,Vahrmeijer Alexander L.

Abstract

ObjectiveNear-infrared (NIR) fluorescence imaging using indocyanine green (ICG) has recently been introduced to improve the sentinel lymph node (SLN) procedure. Several optical tracers have been successfully tested. However, the optimal tracer formulation is still unknown. This study evaluates the performance of ICG–technetium-99m (99mTc)–nanocolloid in relation to 2 most commonly used ICG-based formulas during SLN biopsy in vulvar cancer.Methods and MaterialsTwelve women who planned to undergo SLN biopsy for stage I vulvar cancer were prospectively included. Sentinel lymph node mapping was performed using the dual-modality radioactive and NIR fluorescence tracer ICG–99mTc-nanocolloid. All patients underwent combined SLN localization using NIR fluorescence and the (current) gold standard using blue dye and radioactive guidance.ResultsIn all 12 patients, at least 1 SLN was detected during surgery. A total of 21 lymph nodes (median 2; range, 1–3) were resected. Median time between skin incision and first SLN detection was 8 (range, 1–22) minutes. All resected SLNs were both radioactive and fluorescent, although only 13 (62%) of 21 SLNs stained blue. Median brightness of exposed SLNs, expressed as signal-to-background ratio, was 5.4 (range, 1.8–11.8). Lymph node metastases were found in 3 patients.ConclusionsNear-infrared fluorescence-guided SLN mapping is feasible and outperforms blue dye staining. Premixing ICG with 99mTc-nanocolloid provides real-time intraoperative imaging of the SN and seems to be the optimal tracer combination in terms of intraoperative detection rate of the SN (100%). Moreover, ICG–99mTc-nanocolloid allows the administration of a 5-times lower injected dose of ICG (compared with ICG and ICG absorbed to human serum albumin) and can be injected up to 20 hours before surgery.

Publisher

BMJ

Subject

Obstetrics and Gynaecology,Oncology

Cited by 80 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3