Enhanced Screening for Ectasia Risk: Multimodal Refractive Imaging Observations From the Fellow Unoperated Eye of Patients With Post-Laser In Situ Keratomileusis Ectasia

Author:

Salomão Marcella Q.123,Hoffling-Lima Ana Luisa1,Sena Nelson234,Lopes Bernardo T.124,Guedes Jaime2,Ambrósio Renato1235

Affiliation:

1. Department for Ophthalmology, Universidade Federal de Sao Paulo, Sao Paulo, Brazil;

2. Rio de Janeiro Corneal Tomography and Biomechanics Study Group, Rio de Janeiro, Brazil;

3. Instituto de Olhos Renato Ambrósio and VisareRIO, Rio de Janeiro, Brazil;

4. School of Engineering, University of Liverpool, Liverpool, United Kingdom; and

5. Department of Ophthalmology, Federal University the State of Rio de Janeiro (UNIRIO), Rio de Janeiro, Brazil.

Abstract

Purpose: The aim of this study was to report multimodal refractive imaging findings that may predict ectasia susceptibility on nonoperated eyes of patients who developed post-LASIK ectasia in the fellow eye. Study Design: This is a retrospective case series. Methods: The nonoperated fellow eyes of 5 patients who had unilateral LASIK with progressive ectasia underwent a comprehensive ophthalmologic evaluation and multimodal refractive imaging (MRI), including Pentacam HR and Corvis ST (Oculus; Wetzlar, Germany), along with segmental OCT (RTVue; Optovue, Inc, Fremont, CA). Different objective indices and parameters from the Pentacam, Corvis ST, and OCT were analyzed. Results: None of the 5 cases showed ectasia detection on the Pentacam TKC (topographic keratoconus classification), and inferior–superior (IS) asymmetry values were lower than 1.0 D in all 5 cases. Corneal thicknesses at the thinnest points measured with the Pentacam were 530, 466, 517, 488, and 511 µ, and with the OCT were 512, 460, 508, 480, and 495 µ, in cases 1to 5, respectively. The keratoconus risk scoring system based on OCT measurements demonstrated a high risk in 2 patients. The BAD-D (Belin-Ambrósio Enhanced Ectasia Deviation) was higher than 1.22 in all 5 cases and higher than 1.6 in 2 cases. Four cases had ARTmax (Ambrósio Relational Thickness to the meridian with maximal progression increase) lower than 390. The PRFI (Pentacam Random Forest Index) was equal or higher than 0.12 in all 5 cases, and enhanced posterior elevation, which is calculated using data from the standard elevation map, excluding a 3.5-mm area centered on the thinnest point, was abnormal in all 5 cases. The value of the current version of the tomographic biomechanical index (TBI V1), derived from artificial intelligence (AI) algorithms, which integrate Scheimpflug-based tomography and biomechanical data, was equal or higher than 0.29 in 3 cases. Conclusions: Signs of ectasia susceptibility were detected in all nonoperated eyes based on multimodal imaging. These findings support the clinical relevance of such analysis when screening for ectasia risk among candidates for refractive surgery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3