Masked hypertension in a middle-aged population and its relation to manifestations of vascular disease

Author:

af Geijerstam Peder1,Engvall Jan123,Östgren Carl Johan12,Rådholm Karin14,Nyström Fredrik H.1

Affiliation:

1. Department of Health, Medicine and Caring Sciences, Faculty of Medicine and Health Sciences

2. Center of Medical Image Science and Visualization

3. Department of Clinical Physiology, Linköping University, Linköping, Sweden

4. The George Institute for Global Health, University of New South Wales, Sydney, New South Wales, Australia

Abstract

Background: Masked hypertension is associated with cardiovascular disease (CVD). However, previous large studies have not used the same device to measure office and home blood pressure (BP) and adhered to current home BP measurement recommendations of the European Society of Hypertension. We aimed to characterize masked hypertension and explore its relation to manifestations of CVD. Methods: A randomly selected cohort of 5057 participants aged 50–64 years from the Swedish CardioPulmonary BioImage Study (SCAPIS) was evaluated with office and home BP using the semi-automatic Omron M10-IT oscillometric device. Additional analyses included pulse wave velocity (PWV) and coronary artery calcium score (CACS). Results: Of participants, 4122 did not have current antihypertensive treatment, and were thus included in our analyses. Of these, 2634 (63.9%) had sustained normotension, and 172 (4.2%) had masked hypertension. Participants with masked hypertension vs. sustained normotension were more often men (66.9 vs. 46.2%, P < 0.001). Those with masked hypertension had higher mean PWV [9.3 (95% confidence interval, 95% CI 9.1–9.5) vs. 8.3 (95% CI 8.2–8.4) m/s, P < 0.001] and odds ratio for CACS at least 100 [1.65 (95% CI 1.02–2.68), P = 0.040]. These associations were similar in a posthoc analysis of masked hypertension and sustained normotension, matched for age, sex and systolic office BP. Conclusion: Masked hypertension was associated with markers of CVD. This suggests that home BP is a better predictor of risk, even when the recordings are performed with the same measurement device, in a population-based setting with randomized recruitment.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3