Accurate detection of Korotkoff sounds reveals large discrepancy between intra-arterial systolic pressure and simultaneous noninvasive measurement of blood pressure with brachial cuff sphygmomanometry

Author:

Celler Branko G.1,Yong Andy23,Rubenis Imants2,Butlin Mark3,Argha Ahmadreza4,Rehan Rajan2,Avolio Alberto3

Affiliation:

1. Biomedical Systems Research Laboratory, University of New South Wales

2. Concord Repatriation Hospital, Cardiology, University of Sydney

3. Faculty of Medicine, Health and Human Sciences, Macquarie University

4. Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia

Abstract

Cardiovascular disease is the number 1 cause of death globally, with elevated blood pressure (BP) being the single largest risk factor. Hence, BP is an important physiological parameter used as an indicator of cardiovascular health. Noninvasive cuff-based automated monitoring is now the dominant method for BP measurement and irrespective of whether the oscillometric or the auscultatory method is used, all are calibrated according to the Universal Standard (ISO 81060-2:2019), which requires two trained operators to listen to Korotkoff K1 sounds for SBP and K4/K5 sounds for DBP. Hence, Korotkoff sounds are fundamental to the calibration of all NIBP devices. In this study of 40 lightly sedated patients, aged 64.1 ± 9.6 years, we compare SBP and DBP recorded directly by intra-arterial fluid filled catheters to values recorded from the onset (SBP-K) and cessation (DBP-K) of Korotkoff sounds. We demonstrate that whilst DBP-K measurements are in good agreement, with a mean difference of −0.3 ± 5.2 mmHg, SBP-K underestimates true intra-arterial SBP (IA-SBP) by an average of 14 ± 9.6 mmHg. The underestimation arises from delays in the re-opening of the brachial artery following deflation of the brachial cuff to below SBP. The reasons for this delay are not known but appear related to the difference between SBP and the pressure under the cuff as blood first begins to flow, as the cuff deflates. Linear models are presented that can correct the underestimation in SBP resulting in estimates with a mean difference of 0.2 ± 7.1 mmHg with respect to intra-arterial SBP.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference32 articles.

1. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine;Scheer;Crit Care,2002

2. Un nuovo sfigmomanometro;Riva-Rocci;Gazz Med Torino,1896

3. A contribution to the problem of methods for the determination of the blood pressure;Korotkoff;Rep Imp Mil Med Acad (St Petersburg),1905

4. Measuring blood pressure accurately: new and persistent challenges;Jones;JAMA,2003

5. Improving the quality and accuracy of noninvasive blood pressure measurement by visual inspection and automated signal processing of the Korotkoff sounds;Celler;Physiol Measur,2017

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3