Effectiveness of Kurtosis-Adjusted Cumulative Noise Exposure in Assessing Occupational Hearing Loss Associated With Complex Noise

Author:

Xin Jiarui12,Shi Zhihao3,Qian Peiyi1,Liu Shuangyan2,Hao Yinzhu1,Gao Xiangjin4,Zhou Lifang4,Yang Lei1,Zhang Meibian5

Affiliation:

1. National Institute of Occupational Health and Poison Control, Chinese Center for Disease Control and Prevention, Beijing, China

2. School of Public Health, Hangzhou Normal University, Hangzhou, Zhejiang, China

3. Jiaxing Center for Disease Control and Prevention, Jiaxing, Zhejiang, China

4. School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China

5. Occupational Health and Radiation Protection Institute Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou, Zhejiang, China.

Abstract

Objectives: Occupational noise-induced hearing loss (NIHL) is one of the most prevalent occupational diseases worldwide. Few studies have been reported on applying kurtosis-adjusted noise energy (e.g., kurtosis-adjusted cumulative noise exposure, CNE-K) as a joint indicator for assessing NIHL. This study aimed to analyze the effectiveness of CNE-K in assessing occupational hearing loss associated with complex noise in typical manufacturing industries. Design: A cross-sectional survey of 1404 Chinese manufacturing workers from typical manufacturing industries was conducted. General demographic characteristics, noise exposure data, and noise-induced permanent threshold shifts (NIPTS) at 3, 4, and 6 kHz (NIPTS346) were collected and analyzed. The role of kurtosis in high-frequency noise-induced hearing loss (HFNIHL) was also analyzed. The degree of overlap of the two logistic curves (i.e., between complex noise CNE-K and HFNIHL%, and between Gaussian noise CNE and HFNIHL%) was used to evaluate the effectiveness of CNE-K, using a stratified analysis based on age, sex, industry, or job type. Results: The binary logistic regression analysis showed that in addition to age, sex, exposure duration, and Eight-hour Continuous Equivalent A-weighted Sound Pressure Level (LAeq,8h), kurtosis was a key factor influencing HFNIHL% in workers (odds ratio = 1.18, p < 0.05), and its odds ratio increased with an increase in kurtosis value. Multiple linear regression analysis demonstrated that the contribution of kurtosis to NIPTS346 was second to LAeq,8h. Complex noise led to a higher risk of NIHL than Gaussian noise at frequencies of 3, 4, 6, and 8 kHz after adjusting for age, sex, and CNE (p < 0.05). As kurtosis increased, the notch in the audiogram became deeper, and the frequency at which the notch began to deepen shifted from 3 to 1 kHz. The logistic curve between complex noise CNE-K and HFNIHL% nearly overlapped with that between Gaussian noise CNE and HFNIHL%, and the average difference in HFNIHL% between the two curves decreased from 8.1 to 0.4%. Moreover, the decrease of average difference in HFNIHL% between the two logistic curves was evident in several subgroups, such as male workers, aged <30 and 30 to 50 years, furniture and woodworking industries and gunning and nailing job types with relatively high kurtosis values. Conclusions: Kurtosis, as an indirect metric of noise temporal structure, was an important risk factor for occupational NIHL. Kurtosis-adjusted CNE metric could be more effective than CNE alone in assessing occupational hearing loss risk associated with complex noise.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Speech and Hearing,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3