Electrode Montage Induced Changes in Air-Conducted Ocular Vestibular-Evoked Myogenic Potential

Author:

Raveendran Rajesh Kumar1,Singh Niraj Kumar1

Affiliation:

1. Department of Audiology, All India Institute of Speech and Hearing, Manasagangothri, Mysore, Karnataka, India.

Abstract

Objectives: Stimulus and recording parameters are pivotal for shaping the ocular vestibular-evoked myogenic potential (oVEMP). In the last decade, several attempts were made to identify the optimum electrode placement site to improve the oVEMP responses. A vast majority of these found larger response amplitudes for alternate electrode montages like belly-tendon (BT), chin-referenced (CR), and/or sternum-referenced montages than the clinically used infra-orbital montage. However, no study has yet compared all alternate electrode montages in a simultaneous recording paradigm to eliminate other confounding factors. Also, no study has compared all of them for their test–retest reliability, waveform morphology, and signal-to-noise ratio. Therefore, the decision on which among these electrode montages is best suited for oVEMP acquisition remains opaque. The present study aimed to investigate the effects of various electrode montages on oVEMP’s response parameters and to determine the test–retest reliability of each of these in clinically healthy individuals using a simultaneous recording paradigm. Design: This study had a within-subject experimental design. Fifty-five young healthy adults (age range: 20–30 years) underwent contralateral oVEMP recording using infra-orbital, BT, chin-referenced, and sternum-referenced electrode montages simultaneously using a four-channel evoked potential system. Results: BT montage had a significantly shorter latency, larger amplitude, higher signal-to-noise ratio, and better morphology than other alternate montages (p < 0.008). Further, all electrode montages of the current study showed fair/moderate to excellent test–retest reliability. Conclusions: By virtue of producing significantly better response parameters than the other electrode montages, BT montage seems better suited to the recording of oVEMP than the known electrode montages thus far.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Speech and Hearing,Otorhinolaryngology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3