Auditory Steady-State Responses: Multiplexed Amplitude Modulation Frequencies to Reduce Recording Time

Author:

Sonck Rien1234,Vanthornhout Jonas14,Bonin Estelle23,Francart Tom1

Affiliation:

1. Department of Neurosciences, Research Group Experimental Oto-rhino-laryngology, KU Leuven, Leuven, Belgium

2. Grappe Interdisciplinaire de Génoprotéomique Appliquée-Consciousness, Coma Science Group, University of Liège, Liège, Belgium

3. Brain Center (C2), University Hospital Center of Liège, Liège, Belgium

4. These authors shared first-authorship.

Abstract

Objectives: This study investigated the efficiency of a multiplexed amplitude-modulated (AM) stimulus in eliciting auditory steady-state responses. The multiplexed AM stimulus was created by simultaneously modulating speech-shaped noise with three frequencies chosen to elicit different neural generators: 3.1, 40.1, and 102.1 Hz. For comparison, a single AM stimulus was created for each of these frequencies, resulting in three single AM conditions and one multiplex AM condition. Design: Twenty-two bilaterally normal-hearing participants (18 females) listened for 8 minutes to each type of stimuli. The analysis compared the signal to noise ratios (SNRs) and amplitudes of the evoked responses to the single and multiplexed conditions. Results: The results revealed that the SNRs elicited by single AM conditions were, on average, 1.61 dB higher than those evoked by the multiplexed AM condition (p < 0.05). The single conditions consistently produced a significantly higher SNR when examining various stimulus durations ranging from 1 to 8 minutes. Despite these SNR differences, the frequency spectrum was very similar across and within subjects. In addition, the sensor space patterns across the scalp demonstrated similar trends between the single and multiplexed stimuli for both SNR and amplitudes. Both the single and multiplexed conditions evoked significant auditory steady-state responses within subjects. On average, the multiplexed AM stimulus took 31 minutes for the lower bound of the 95% prediction interval to cross the significance threshold across all three frequencies. In contrast, the single AM stimuli took 45 minutes and 42 seconds. Conclusions: These findings show that the multiplexed AM stimulus is a promising method to reduce the recording time when simultaneously obtaining information from various neural generators.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3