Effect of Real-Ear Adjusted Stimuli on Vestibular Evoked Myogenic Potential Variability in Children and Young Adults

Author:

Hernon Erin E.12,Patterson Jessie N.1,Fitzpatrick Denis1,Janky Kristen L.1

Affiliation:

1. Department of Audiology, Boys Town National Research Hospital, Omaha, Nebraska, USA

2. Department of Communication Sciences and Disorders, James Madison University, Harrisonburg, Virginia, USA.

Abstract

Objectives: There is large variability in cervical and ocular vestibular evoked myogenic potential (c- and oVEMP) amplitudes. One potential source of variability is differences in ear canal shape and size. Real ear-to-coupler difference (RECD) values are used to measure the acoustic environment of an individual’s ear canal. RECD may be a useful measure to calibrate air conducted VEMP stimuli, which are elicited at high intensities and may put patients at risk of unsafe sound exposure. A recommendation for avoiding unsafe exposure is to use a 125 dB SPL stimulus for individuals with an equivalent ear canal volume (ECV) ≥ 0.9 mL and a 120 dB SPL stimulus for individuals with a smaller ECV. The purpose of this project was to determine if using a stimulus calibrated in the ear using RECD values significantly reduces intra-subject and inter-subject VEMP amplitude variability. We hypothesized that using a RECD-calibrated stimulus would significantly reduce inter-subject amplitude variability but not significantly reduce intra-subject variability. We further hypothesized that an RECD-adjusted VEMP stimulus would better protect against delivering unsafe sound exposure compared to the method of using ECV alone. Design: Eleven children (4 to 9 years), 10 adolescents (10 to 18 years), and 10 young adults (20 to 40 years) with normal hearing, tympanometry, vestibular and neurological function participated. On all subjects, RECD was measured twice per ear to account for test-retest reliability. cVEMP and oVEMP were then recorded bilaterally with a 500 Hz tone burst at a traditional and an adjusted VEMP intensity level. The traditional intensity level was 125 dB SPL for individuals with ≥ 0.9 mL ECV and 120 dB SPL for individuals with ≤ 0.8 mL ECV. The adjusted intensity level was calculated by subtracting the average 500 Hz RECD measured values from the 500 Hz normative RECD value. This value was applied as a correction factor to a 125 dB SPL stimulus. Peak to peak amplitudes were recorded and used to calculate asymmetry ratios. Results: Young children had significantly smaller ECVs compared to adolescents and young adults. Young children had larger RECDs; however, this was not significant in post hoc analyses. The method of calibration had no significant effect on intra-subject variability for cVEMP [F(1, 27)= 0.996, p = 0.327] or oVEMP [F(1, 25)= 1.679, p = 0.206]. The method of calibration also had no significant effect on inter-subject amplitude variability for cVEMP [F(1, 120)= 0.721, p = 0.397] or oVEMP [F(1, 120)= 0.447, p = 0.505]. Both methods of calibration adequately protected against unsafe exposure levels. However, there were subjects with ECVs ≥ 0.9 mL who approached unsafe exposure levels from the ECV-calibrated stimulus, suggesting there may be rare cases in which a 125 dB SPL stimulus is unsafe, even for patients with larger ECVs. Conclusions: The calibration method made no significant difference in intra- or inter-subject variability, indicating that the acoustic environment of the outer ear is not significantly contributing to VEMP amplitude variability. The RECD-adjusted stimulus is effective in protecting against unsafe exposure levels for two trials of both c- and oVEMPs. There may be instances where more than two trials of each test are required, which increases the effective stimulation level. Clinicians should be cautious when delivering VEMPs and not unnecessarily expose patients to unsafe levels of sound.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Speech and Hearing,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3