Percutaneous transluminal angioplasty and stenting for severe stenosis of the intracranial carotid artery and its branches: Comparison of the Wingspan stent vs the Credo stent

Author:

Lin Te-Ming12,Wu Chia-Hung123,Chung Chih-Ping234,Yu Kai-Wei12,Tai Wei-An123,Luo Chao-Bao125,Lirng Jiing-Feng12,Chang Feng-Chi12

Affiliation:

1. Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan, ROC

2. School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC

3. Institute of Clinical Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC

4. Department of Neurology, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan, ROC

5. Department of Biomedical Engineering, Yuanpei University of Medical Technology, Hsinchu, Taiwan, ROC

Abstract

Background: Despite the widespread use of the Wingspan stent system for treating severe medically refractory intracranial artery stenosis (SMR-ICAS), a new Credo stent system was approved because it could integrate stent delivery within the balloon catheter. However, the therapeutic outcomes of these two systems have not been compared. This preliminary study aimed to compare the results of percutaneous angioplasty and stenting (PTAS) in SMR-ICAS patients treated with either Wingspan or Credo stents within the anterior cerebral circulation. Methods: SMR-ICAS patients with >70% stenosis in the anterior circulation who underwent PTAS using either the Wingspan or Credo stent system were retrospectively analyzed. We evaluated the technical success, safety, and outcomes of the two-stent systems. Results: A total of 29 patients were analyzed, including 17 patients treated with Wingspan stents and 12 with Credo stents. The outcomes of the Wingspan stent vs Credo stent were as follows: technical success (16/17 [94%] vs 11/12 [92%], p = 1.00); periprocedural intracranial hemorrhage (2/17 [12%] vs 0/12 [0%], p = 0.50); silent embolic ischemic lesions on periprocedural magnetic resonance imaging (MRI) (13/17 [76%] vs 7/12 [58%], p = 0.42); and significant (>50%) in-stent restenosis in 1 year (4/17 [24%] vs 2/12 [17%], p = 1.00). No recurrent stroke or mortality was noted within 30 days after the procedures or during the 1-year follow-up period. Conclusion: The technical success, safety, and outcomes of the Credo stent system were comparable to those of the Wingspan stent system in the management of SMR-ICAS patients. Further large-scale studies are warranted to substantiate these findings.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference27 articles.

1. Epidemiology of intracranial stenosis.;Suri;J Neuroimaging,2009

2. Atherosclerotic intracranial arterial stenosis: risk factors, diagnosis, and treatment.;Holmstedt;Lancet Neurol,2013

3. The stenting versus aggressive medical therapy for intracranial arterial stenosis trial: reanalysis using the FDA “on label” criteria.;Qureshi;J Neuroimaging,2020

4. The 2023 Taiwan Stroke Society Guidelines for the management of patients with intracranial atherosclerotic disease.;Lin;J Chin Med Assoc,2023

5. Stenting versus aggressive medical therapy for intracranial arterial stenosis.;Chimowitz;N Engl J Med,2011

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3