Diagnostic ability of macular nerve fiber layer thickness measured by swept-source OCT in preperimetric glaucoma

Author:

Yeh Shih-Jung1,Su Yi-Wen2,Chen Mei-Ju23

Affiliation:

1. Department of Ophthalmology, Taipei City Hospital, ZhongXing Branch, Taipei, Taiwan, ROC

2. Department of Ophthalmology, Taipei Veterans General Hospital, Taipei, Taiwan, ROC

3. School of Medicine, National Yang Ming Chao Tung University, Taipei, Taiwan, ROC

Abstract

Background: We evaluated the diagnostic ability of macula retinal nerve fiber layer (mRNFL) thickness in preperimetric glaucoma (PPG) patients. Methods: This prospective study included 83 patients with PPG and 83 age- and refractive error-matched normal control subjects. PPG was defined as a localized RNFL defect corresponding to glaucomatous optic disc changes with a normal visual field test. We used spectral-domain (SD) OCT to measure the circumpapillary RNFL (cpRNFL) thickness and macular ganglion cell-inner plexiform layer (GCIPL) thickness. Swept-source (SS) OCT was used to measure cpRNFL thickness, macular ganglion cell layer + inner plexiform layer (IPL) thickness (GCL+), and macular ganglion cell layer + IPL+ mRNFL thickness (GCL++). The mRNFL thickness was defined as GCL++ minus GCL+. To evaluate the diagnostic power of each parameter, the area under the receiver operating characteristics curve (AUROC) was analyzed to differentiate PPG from the normal groups. Results: Using SD-OCT, all GCIPL parameters and most cpRNFL parameters, except at the nasal and temporal quadrant, were significantly lower in PPG versus normal controls. PPG eyes had significantly smaller values than normal controls for all cpRNFL and GCL parameters measured by SS-OCT, except mRNFL at the superonasal area. The inferotemporal GCL++ had the largest AUROC value (0.904), followed by inferotemporal GCL+ (0.882), inferotemporal GCIPL thickness (0.871), inferior GCL++ (0.866), inferior cpRNFL thickness by SS-OCT (0.846), inferior cpRNFL thickness by SD-OCT (0.841), and inferotemporal mRNFL thickness (0.840). The diagnostic performance was comparable between inferotemporal mRNFL thickness and the best measures of GCL (inferotemporal GCL++, p = 0.098) and cpRNFL (inferior cpRNFL thickness by SS-OCT, p = 0.546). Conclusion: The diagnostic ability of mRNFL thickness was comparable to that of the best measures of cpRNFL and GCL analysis for eyes with PPG. Therefore, mRNFL thickness could be a new parameter to detect early structural changes in PPG.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3