Procedural safety of transcatheter aortic valve replacement with Portico valve: a systematic review

Author:

Jaiswal Vikash12,Wajid Zarghoona3,Suresh Vinay4,Hanif Muhammed5,Rajak Kripa6,Halder Anupam6,Endurance Evbayekha7,Aiwuyo Henry7,Choudhari Jinal1,Naz Sidra8,Ang Song P.9,Shrestha Abhigan B.10

Affiliation:

1. Division of Cardiovascular Research, Larkin Community Hospital, South Miami, Florida

2. JCCR Cardiology Research, Varanasi, India

3. Department of Internal Medicine, Wayne State University School of Medicine, Michigan

4. Department of Medicine, King George’s Medical University, Lucknow

5. Department of Internal Medicine, SUNY Upstate Medical University, Syracuse, New York

6. Department of Internal Medicine, UPMC Harrisburg, Pennsylvania

7. Internal Medicine Department, St. Luke’s Hospital, St. Louis, Missouri

8. The University of Texas, MD Anderson Cancer Center, Texas

9. Department of Medicine, Bangalore Medical College and Research Institute, Karnataka

10. Department of Internal Medicine, M Abdur Rahim Medical College, Dinajpur, Bangladesh

Abstract

Background: The Portico transcatheter aortic heart valve is a self-expandable, fully resheathable bioprosthetic valve with a nitinol frame and porcine pericardial sealing cuff. It has been used among symptomatic severe aortic stenosis (AS) who are at high or extreme surgical risk. However, till date very few studies has been reported with inconclusive evidence for its postprocedure safety outcomes. Objective: The authors aim to evaluate the safety of the Portico transcatheter aortic valve replacement system among patients with AS. Methodology: The authors conducted a systematic literature search on PubMed, Embase, and Scopus from inception till 10th April 2023 by using predefined MESH terms using ‘AND’ and ‘OR’. The following search terms were used: ‘Aortic Stenosis’ AND ‘Transcatheter aortic valve replacement’ OR ‘Portico valve’. Finally, descriptive statistics were used to summarize the data in this paper. The mean and SD were adopted to describe continuous variables, whereas frequencies and percentages were used for dichotomous data. Results: A total of 7 studies with 2782 patients were included in the analysis. The mean age of patients was 82.3 years, and 54.63% were female. The most common comorbidity was hypertension (65.21%) and diabetes mellitus (26.45%). Among patients of AS with Portico valve implants, postprocedural outcomes including 30-day mortality (2.32%), cardiovascular mortality (2.37%), stroke (2.23%), myocardial infarction (0.94%), major bleeding (3.97%), major vascular complications (4.91%), acute kidney injury (1.37%), and permanent pacemaker implantations in 15.73% patients were reported. Overall, device success was observed in 95.82% of patients. Conclusion: Transcatheter aortic valve replacement with the repositionable Portico valve, a new bioprosthesis, appears to have a low postprocedural mortality rate and other clinical outcomes in high-risk patients with severe AS.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3