Design of well-matched end-structure of anatomical proximal femoral locking plate based on computer-assisted imaging combined with 3D printing technology: a quality improvement study

Author:

Jia Xiaoyang1ORCID,Zhang Kun2ORCID,Qiang Minfei3ORCID,Han Qinghui2,Zhao Guojun4,Wu Ying5ORCID,Chen Yanxi3ORCID

Affiliation:

1. Department of Orthopedic Surgery, Changzheng Hospital, Naval Medical University (Second Military Medical University)

2. Department of Orthopedic Trauma, East Hospital, Tongji University School of Medicine

3. Department of Orthopedic Surgery, Zhongshan Hospital, Fudan University, Shanghai

4. Walkman biomaterial CO., LTD, Tianjin

5. Department of Biostatistics, Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Public Health, Southern Medical University, Guangdong, Guangzhou, China

Abstract

Background: The extramedullary locking plate system was the common internal fixation method for hip fractures. However, common plates were poorly matched to femur, which was because they were designed based on anatomical parameters of the Western populations. Therefore, the aim was to design an end-structure of the anatomical proximal femoral locking plate that closely matched the anatomy of the Chinese population. Materials and methods: From January 2010 to December 2021, consecutive patients aged 18 years and older who underwent a full-length computed tomography scan of the femur were included. The end-structure (male and female model) of the anatomical proximal femoral locking plate was designed based on anatomical parameters of femurs that were measured in three-dimensional space using computer-assisted virtual technology. The match degree between the end-structure and femur were evaluated. Inter-observer and intra-observer agreement for the evaluation of match degree was assessed. The matching evaluation based on a three-dimensional printing model was regarded as the gold standard to assess the reliability. Results: A total of 1672 patients were included, with 701 men and 971 women. Significant differences were seen between male and female for all parameters of the proximal femur (all P<0.001). All match degree of end-structure was over 90%. Inter-observer and intra-observer agreement was almost perfect (all kappa value, >0.81). The sensitivity, specificity, and percentage of correct interpretation of matching evaluation in the computer-assisted virtual model was all greater than 95%. From femur reconstruction to completion of internal fixation matching, the process takes about 3 min. Moreover, reconstruction, measurement, and matching were all completed in one system. Conclusions: The results showed that based on the larger sample of femoral anatomical parameters, a highly matching end-structure of anatomical proximal femoral locking plate for Chinese population could be designed with use of computer-assisted imaging technology.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3