Trust Your Fingers: Determining the Reliability and Validity of the Measurement of the Diastasis of the Rectus Abdominis Muscle by Palpation and Tape Measure

Author:

Zavagni Käthi1,Stauffer Mirjam1,Meier Hannah2,Knols Rudolf H.134,Kimmich Nina5

Affiliation:

1. Department of Physiotherapy Occupational Therapy, University Hospital of Zurich, Zurich, Switzerland.

2. Department of Physiotherapy, Hirslanden Klink, Aarau, Switzerland.

3. Physiotherapy Occupational Therapy Research Center, Directorate of Research and Education, University Hospital of Zurich, Zurich, Switzerland.

4. Department of Health Sciences and Technology, Institute of Human Movement Sciences and Sport, ETH Zurich, Zurich, Switzerland.

5. Division of Obstetrics, University Hospital of Zurich, Zurich, Switzerland.

Abstract

Background: Diastasis of the rectus abdominis muscle (DRAM) occurs in about 60% of pregnant women and often persists after delivery. Currently, the reference standard to measure DRAM is ultrasonography, and physiotherapy is considered first-line treatment. Most physiotherapists do not base their DRAM assessment on ultrasonography but instead on palpatory evaluation with tape measures. This method is neither standardized nor has been tested for its reliability or validity in women with interrectus distance (IRD) of 30 mm and greater. Objectives: To assess the reliability of the measurements of DRAM by palpation with tape measure and to evaluate its validity compared with ultrasonography. Study Design: Prospective observational study. Methods: Two physiotherapists assessed test-retest, intra- and interrater reliability of this method in 20 women with IRD of 30 mm and greater, using intraclass correlations (ICC) and compared the values with ultrasonography to establish its validity using Spearman ρ and Bland-Altman plots. The interval between the 2 sessions was 7 days and greater. Results: The ICC values for test-retest reliability ranged from 0.67 to 0.95 and between 0.40 and 0.85 for intrarater reliability. The ICC values for interrater reliability ranged from 0.13 to 0.29. In terms of validity, correlations were inconsistent with Spearman ρ ranging from −0.24 to 0.74. Conclusion: Single palpatory measurement with tape above the umbilicus and during partial curl-up might detect changes in IRD of 15.5 mm and greater over time in women with IRD of 30 mm and greater. It cannot replace ultrasonographic measurements in accuracy but might be the only available option for IRDs larger than the ultrasonographic probe.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3