Incidence of Residual Clot Strands in Saphenous Vein Grafts after Endoscopic Harvest

Author:

Burris Nicholas1,Schwartz Kimberly1,Brown Jamie1,Kwon Michael1,Pierson Richard1,Griffith Bartley1,Poston Robert1

Affiliation:

1. Division of Cardiac Surgery, University of Maryland School of Medicine, Baltimore, Maryland.

Abstract

Objective Strands of clot are frequently flushed out of saphenous vein grafts (SVG) during preparation for grafting, particularly those that are endoscopically harvested. However, saline distention at uncontrolled pressures increases graft thrombogenicity and the risk of early failure after coronary artery bypass grafting. The purpose of this prospective investigation was to define the incidence of intraluminal clot within endoscopically harvested SVG and the effect of attempted removal by saline distention. Methods Endoscopically harvested SVG were intraoperatively prepared for grafting by using saline distention at uncontrolled pressure (n = 24) or without distension (n = 20). Optical coherence tomography, a catheter-based infrared imaging system, was used to identify and characterize intraluminal clot strands in surplus SVG segments (average length for analysis, 4.9 ± 2.6 cm). These segments were also assessed for luminal tissue factor activity and percent endothelial integrity by CD31-directed immunohistochemistry. Results Clot strands were observed in 45.4% (20 of 44) of imaged SVG segments (severity of observed clots: 54%, mild; 32%, moderate; 14%, severe). Compared with grafts distended with saline, vein segments that were not distended displayed significantly higher endothelial integrity (60.1% ± 27.2% versus 24.7% ± 24.1%, P < 0.05) and lower tissue factor activity (1.28 ± 0.95 versus12.3 ±5.5 U/cm2, P < 0.001) despite having a higher incidence of clot stands (65.0% versus 29.1%, P < 0.02, Fisher exact test). Static flow was observed in veins during endoscopic harvest. Conclusions Clot strands of varying severity are a common finding after endoscopic vein harvest. Saline distention is not completely effective in removing clot strands and increases overall graft thrombogenicity. Therefore, prevention of clot or less traumatic methods of removing clot are indicated.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3