Transcatheter Valve Replacement: New concepts for Microsurgery inside the Heart

Author:

Brecht Ralf1,Friedrich Maximilian1,Heinisch Paul Philipp1,Plonien Katharina1,Akra Bassil1,Hagl Christian1,Khoynezhad Ali2,Lutter Georg3,Bombien René123

Affiliation:

1. Clinic of Cardiac Surgery, University of Munich-Grosshadern, Munich, Germany

2. Division of Cardiothoracic Surgery, Cedars Sinai Medical Center, Los Angeles, CA USA

3. Department of Cardiovascular Surgery, University Hospital of Schleswig-Holstein, Campus Kiel, Kiel, Germany.

Abstract

Objective Transcatheter aortic valve implantation gained clinical relevance with an impressive and peerless power; however, the procedure induces unsolved complications such as paravalvular leakage, occlusion of coronary ostia, and vascular complications. The safe removal of bulky calcified valves will improve the outcome, well known through the open surgical procedure. In this article, a new stapler-based resection and implantation device as well as a new approach for valve isolation during normal heart cycle without extracorporeal circulation will be analyzed. Methods First, a novel stapler-based instrument for transapical aortic valve replacement [removal and implantation; stapler-based aortic valve replacement (StapAVR)] was constructed and analyzed in an aortic debris model. Artificial aortic valves (N = 20), containing fluorescent granules to simulate the calcification, were placed into an aortic model in anatomical supine position (DP) and right-sided lateral position (RP). With the StapAVR, resection before implantation was performed in a water-filled basin. Black light was used for debris visualization. The procedures have been digitally recorded and analyzed due to procedural times, and the debris amount in thoracic side branches. Second, an enhanced prototype of the pulmonary valve isolation chamber (PVIC) was analyzed in porcine in vitro (n = 10) and in vivo models (n = 1). This PVIC contains a microaxial pump (Impella; Abiomed, Aachen, Germany) in the central bypass channel. It was deployed through the right ventricular wall. Once the PVIC was in place, the pump was started before isolating the valve. The complete hemodynamic monitoring was digitally recorded. Results The deployment of the StapAVR in the correct position and the valve resection time took a mean (SD) of 95.8 (19) seconds in DP and 90.1 (18) seconds in RP. Fluorescent debris was found: in the left coronary artery, 22% in DP and 7% in RP; in the ascending aorta, 0% in DP and 11% in RP; in the aortic bulbous, 5% in DP and 10% in RP; in the left ventricle, 8% in DP and 14% in RP; in the brachiocephalic trunk, 4% in DP and 9% in RP; and in the descending aorta, 46% in DP and 1% in RP. Consecutive valved stent implantation was performed without complications. The PVIC deployment time in vivo was 5 minutes, replacements included. The total valve isolation time was 21 minutes, with a mean (SD) bypass flow of 2.1 (0.4) L/min. The oxygen saturation showed a median of 91% (range, 83%–97%), and the median arterial blood pressure was 69 mm Hg (systolic; range, 47–120 mm Hg) and 40mm Hg (diastolic; range, 32–56 mm Hg) without the use of inotropes or vasopressors. Electrocardiogram confirmed sinus rhythm during isolation. Conclusions The resection of the artificial valves followed by valved stent implantation was possible with the StapAVR. In vivo, the procedure will be carried out under rapid pacing and sudden vacuum; however, the results of this in vitro debris model underline the need for isolation or filter devices during transcatheter aortic valve implantation to avoid embolization. Secondly, the use of the pump-advanced PVIC showed stable heart function for 21 minutes under isolated pulmonary valve conditions. This time will be adequate to remove bulky calcifications and to implant a valved stent. Improvements of both prototypes are ongoing. Nevertheless, the presented concepts showed promising application possibilities in the future.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Native Aortic Valve Resection Using a Novel Blade-Based Device;Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery;2024-03

2. Robotic-assisted microvascular surgery: skill acquisition in a rat model;Journal of Robotic Surgery;2017-08-10

3. Endovascular resection of the native aortic valve before transcatheter aortic valve implantation: state of the art and review;European Journal of Cardio-Thoracic Surgery;2016-03-31

4. Resection of Calcified Aortic Heart Leaflets In Vitro by Q-Switched 2 µm Microsecond Laser Radiation;Journal of Cardiac Surgery;2014-12-21

5. Cardiac Surgery;Cardio-Thoracic, Vascular, Renal and Transplant Surgery;2013-10-26

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3