Intraoperative fluoroscopic radiation in orthopedic trauma: correlation with surgery type and surgeon experience

Author:

Fabião Luís12ORCID,Ribau Ana12,Lemos Carolina234,Rodrigues-Pinto Ricardo12

Affiliation:

1. Spinal Unit (UVM) Department of Orthopaedics, Centro Hospitalar Universitário do Porto, Porto, Portugal

2. ICBAS—Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Porto, Portugal

3. UnIGENe, IBMC, Instituto de Biologia Molecular e Celular, Porto, Portugal

4. i3S, Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Porto, Portugal

Abstract

ABSTRACT Background: While fluoroscopy is widely used in orthopedic trauma surgeries, it is associated with harmful effects and should, therefore, be minimized. However, reference values for these surgeries have not been defined, and it is not known how surgeon experience affects these factors. The aims of this study were to analyze the radiation emitted and exposure time for common orthopedic trauma surgeries and to assess whether they are affected by surgeon experience. Methods: Data from 1842 trauma orthopedic procedures were retrospectively analyzed. A total of 1421 procedures were included in the analysis. Radiation dose and time were collected to identify reference values for each surgery and compared for when the lead surgeon was a young resident, a senior resident, or a specialist. Results: The most performed surgeries requiring fluoroscopy were proximal femur short intramedullary nailing (n = 401), ankle open reduction and internal fixation (ORIF) (n = 141), distal radius ORIF (n = 125), and proximal femur dynamic hip screw (DHS) (n = 114). Surgeries using higher radiation dose were proximal femur long intramedullary nailing (mean dose area [DAP]): 1361.35 mGycm2), proximal femur DHS (1094.81 mGycm2), and proximal femur short intramedullary nailing (891.41 mGycm2). Surgeries requiring longer radiation time were proximal humerus and/or humeral shaft intramedullary nailing (02 mm:20 ss), proximal femur long intramedullary nailing (02 mm:04 ss), and tibial shaft/distal tibia intramedullary nailing (01 mm:49 ss). Senior residents required shorter radiation time when performing short intramedullary nailing of the proximal femur than young residents. Specialists required more radiation dose than residents when performing tibial nailing and tibial plateau ORIF and required longer radiation time than young residents when performing tibial nailing. Conclusions: This study presents mean values of radiation dose and time for common orthopedic trauma surgeries. Orthopedic surgeon experience influences radiation dose and time values. Contrary to expected, less experience is associated with lower values in some of the cases analyzed.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Biochemistry, Genetics and Molecular Biology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3