A Randomized Controlled Trial Comparing the Cuffed Oropharyngeal Airway and the Laryngeal Mask Airway in Spontaneously Breathing Anesthetized Adults

Author:

Greenberg Robert S.,Brimacombe Joseph MB,Berry Alison,Gouze Victoria,Piantadosi Steven,Dake Elizabeth M.

Abstract

Background The cuffed oropharyngeal airway (COPA), a modified Guedel airway, was compared with the laryngeal mask airway (LMA) during spontaneous breathing anesthesia. Specifically examined were ease of use, physiologic tolerance, and the frequency of problems. Methods Adult patients consented to random (2:1) assignment to either COPA (n = 302) or LMA (n = 151) for airway management during anesthesia with propofol, nitrous oxide, and oxygen. Results Ease of insertion was similar, but the first-time successful insertion rate was higher with the LMA (COPA, 81% compared with LMA, 89%; P = 0.05). More brief manipulations (head tilt, chin lift, jaw thrust) were reported in the COPA group (average total number of manipulations: COPA, 1.1 +/- 1.6 compared with LMA, 0.1 +/- 0.2; P < 0.001). Continuous airway support was used more frequently in the COPA group (COPA, 30% compared with LMA, 0%; P < 0.0005). The incidences of aspiration, regurgitation, laryngospasm, wheezing, succinylcholine administration, oxygen saturation (SpO2) < 92%, failed use, and minor intraoperative problems were similar. When the airways were removed, blood was detected on the COPA less frequently than on the LMA (COPA, 5.8% compared with LMA, 15.3%; P = 0.001). The incidence of early and late sore throat was greater with the LMA (early: COPA, 4.7% compared with LMA, 21.9% [P = 0.001]; late: COPA, 8.4% compared with LMA, 16.1%; P = 0.01). The LMA did better than the COPA when anesthetists analyzed the technical aspects of the two devices. Conclusions Although the COPA and LMA are equivalent devices in terms of physiologic alterations and overall clinical problems associated with their use, the LMA was associated with a higher first-time insertion rate and fewer manipulations, suggesting that it is easier to use. The COPA was associated with less blood on the device and fewer sore throats, suggesting it may cause less pharyngeal trauma. Ultimately, both devices were similar in establishing a safe and effective airway for spontaneously breathing anesthetized adults.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference14 articles.

Cited by 98 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3