Author:
Comunale Mark E.,Body Simon C.,Ley Catherine,Koch Colleen,Roach Gary,Mathew Joseph P.,Herskowitz Ahvie,Mangano Dennis T.
Abstract
Background
Transesophageal echocardiography (TEE) and Holter electrocardiography (ECG) are used to detect intraoperative ischemia during coronary artery bypass graft surgery (CABG). Concordance of these modalities and sensitivity as indicators of adverse perioperative cardiac outcomes are poorly defined. The authors tried to determine whether routine use of Holter ECG and TEE in patients with CABGs has clinical value in identifying those patients in whom myocardial infarction (MI) is likely to develop.
Methods
A total of 351 patients with CABG and both ECG- and TEE-evaluable data were examined for the occurrence of ischemia and infarction. The TEE and five-lead Holter ECGs were performed continuously during cardiac surgery. The incidence of MI (creatine kinase-MB > or = 100 ng/ml) within 12 h of arrival in the intensive care [ICU] unit, new ECG Q wave on ICU admission or on the morning of postoperative day 1, or both, were recorded.
Results
Electrocardiographic or TEE evidence of intraoperative ischemia was present in 126 (36%) patients. The concordance between modalities was poor (positive concordance = 17%; Kappa statistic = 0.13). Myocardial infarction occurred in 62 (17%) patients, and 32 (52%) of them had previous intraoperative ischemia. Of these, 28 (88%) were identified by TEE, whereas 13 (41%) were identified by ECG. Prediction of MI was greater for TEE compared with ECG.
Conclusions
Wall-motion abnormalities detected by TEE are more common than S-T segment changes detected by ECG, and concordance between the two modalities is low. One half of patients with MI had preceding ECG or TEE ischemia. Logistic regression revealed that TEE is twice as predictive as ECG in identifying patients who have MI.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Anesthesiology and Pain Medicine
Cited by
97 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献