Dural Puncture with a 27-Gauge Whitacre Needle as Part of a Combined Spinal–Epidural Technique Does Not Improve Labor Epidural Catheter Function

Author:

Thomas John A.1,Pan Peter H.2,Harris Lynne C.3,Owen Medge D.2,D’Angelo Robert2

Affiliation:

1. Assistant Professor.

2. Associate Professor.

3. Research Coordinator.

Abstract

Background This prospective, double-blind, randomized study was designed to examine whether the combined spinal-epidural technique without subarachnoid drug administration improved epidural catheter function when compared with the traditional epidural technique. Methods After institutional review board approval and informed consent, 251 healthy laboring parturients were randomly assigned to either group DP (combined spinal-epidural technique with 27-gauge Whitacre needle dural puncture but without subarachnoid drug administration) or group NoDP (traditional epidural technique). Patient-controlled epidural analgesia was initiated with 0.11% bupivacaine and 2 microg/ml fentanyl. Top-up doses in 5-ml increments of 0.25% bupivacaine were administered if needed. Previous power analysis revealed that a sample size of 108 patients/group was needed to show a clinically useful reduction of the catheter manipulation rate from 32% to 15%. Results In groups DP and NoDP, 107 and 123 evaluable patients, respectively, completed the study. Demographics and outcome variables measured, including epidural catheter manipulation and replacement rate, sacral sparing, unilateral block, number of top-up doses, average hourly epidural drug usage, highest sensory blockade level, and labor analgesia quality, were not different between groups. A subgroup of 18 patients without cerebral spinal fluid return during dural puncture had a higher catheter replacement rate than those of groups DP and NoDP, but it did not reach statistical significance. Conclusions Dural puncture with a 27-gauge Whitacre needle without subarachnoid drug administration during combined spinal-epidural labor analgesia did not improve epidural labor analgesia quality or reduce catheter manipulation or replacement rate when compared with a traditional epidural technique.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference26 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3