Cardiorespiratory Effects of Positive End-expiratory Pressure during Progressive Tidal Volume Reduction (Permissive Hypercapnia) in Patients with Acute Respiratory Distress Syndrome

Author:

Ranieri V. Marco,Mascia Luciana,Fiore Tommaso,Bruno Francesco,Brienza Antonio,Giuliani Rocco

Abstract

Background In patients with acute respiratory distress syndrome (ARDS), the ventilatory approach is based on tidal volume (VT) of 10-15 ml/kg and positive end-expiratory pressure (PEEP). To avoid further pulmonary injury, decreasing VT and allowing PaCO2 to increase (permissive hypercapnia) has been suggested. Effects of 10 cmH2O of PEEP on respiratory mechanics, hemodynamics, and gas exchange were compared during mechanical ventilation with conventional (10-15 ml/kg) and low (5-8 ml/kg) VT. Methods Nine sedated and paralyzed patients were studied. VT was decreased gradually (50 ml every 20-30 min). Static volume-pressure (V-P) curves, hemodynamics, and gas exchange were measured. Results During mechanical ventilation with conventional VT, V-P curves on PEEP 0 (ZEEP) exhibited an upward convexity in six patients reflecting a progressive reduction in compliance with inflating volume, whereas PEEP resulted in a volume displacement along the flat part of this curve. After VT reduction, V-P curves in the same patients showed an upward concavity, reflecting progressive alveolar recruitment with inflating volume, and application of PEEP resulted in alveolar recruitment. The other three patients showed a V-P curve with an upward concavity; VT reduction increased this concavity, and application of PEEP induced greater alveolar recruitment than during conventional VT. With PEEP, cardiac index decreased by, respectively, 31% during conventional VT and 11% during low VT (P < 0.01); PaO2 increased by 32% and 71% (P < 0.01), respectively, whereas right-to-left venous admixture (Qs/Qt) decreased by 11% and 40%, respectively (P < 0.01). The greatest values of PaO2, static compliance, and oxygen delivery and the lowest values of Qs/Qt (best PEEP) were obtained during application of PEEP with low VT (P < 0.01). Conclusions Although PEEP induced alveolar hyperinflation in most patients during mechanical ventilation with conventional VT, at low VT, there appeared to be a significant alveolar collapse, and PEEP was able to expand these units, improving gas exchange and hemodynamics.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference39 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3