Effects of Two Target-controlled Concentrations (1 and 3 ng/ml) of Remifentanil on MACBARof Sevoflurane

Author:

Albertin Andrea1,Casati Andrea1,Bergonzi Piercarlo2,Fano Greta2,Torri Giorgio3

Affiliation:

1. Staff Anesthesiologist.

2. Anesthesia Fellow.

3. Professor of Anesthesiology.

Abstract

Background The aim of this prospective, randomized, double-blind study was to determine the effects of two different target-controlled concentrations of remifentanil (1 and 3 ng/ml) on the sevoflurane requirement for blunting sympathetic responses after surgical incision (MACBAR). Methods Seventy-four patients aged 20-50 yr, with American Society of Anesthesiologists physical status I, were anesthetized with propofol, cisatracurium, and sevoflurane with a mixture of 60% nitrous oxide in oxygen. Then, patients were randomly allocated to receive no remifentanil infusion (n = 27) or a target-controlled plasma concentration of 1 ng/ml (n = 27) or 3 ng/ml remifentanil (n = 20). Sympathetic responses to surgical incision (presence or absence of an increase in either heart rate or mean arterial blood pressure of 15% or more above the mean of the values measured during the 2 min before skin incision) were determined after a 20-min period of stable end-tidal sevoflurane and target-controlled remifentanil concentrations. Predetermined end-tidal sevoflurane concentrations and the MACBAR for each group were determined using an up-and-down sequential-allocation technique. Results The MACBAR of sevoflurane was higher in the group receiving no remifentanil (2.8% [95% confidence interval: 2.5-3.0%]) as compared with patients of the groups receiving 1 ng/ml (1.1% [0.9-1.3%]; P = 0.012) and 3 ng/ml remifentanil (0.2% [0.1-0.3%]; P = 0.006). When considering a minimum anesthetic concentration (MAC) value in this age population and the contribution of 60% nitrous oxide (0.55 MAC), the combined MACBAR values, expressed as multiples of the MAC, were 1.95 MAC, 1.1 MAC, and 0.68 MAC, in the three groups, respectively. Conclusion A target-controlled concentration of 1 ng/ml remifentanil results in a 60% decrease in the MACBAR of sevoflurane combined with 60% nitrous oxide. Increasing the target concentration of remifentanil to 3 ng/ml produces a further 30% decrease in the MACBAR values of sevoflurane.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference28 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3