Variability of Target-controlled Infusion Is Less Than the Variability after Bolus Injection

Author:

Hu Chuanpu1,Horstman Damian J.2,Shafer Steven L.3

Affiliation:

1. Assistant Director, Biostatistics, Sanofi-Synthelabo Research, Malvern, Pennsylvania.

2. Resident in Anesthesia, Stanford University.

3. Staff Anesthesiologist, Palo Alto VA Health Care System; Professor of Anesthesia, Stanford University; and Adjunct Professor of Biopharmaceutical Science, University of California at San Francisco, San Francisco, California.

Abstract

Background Target-controlled infusion (TCI) drug delivery systems deliver intravenous drugs based on pharmacokinetic models. TCI devices administer a bolus, followed by exponentially declining infusions, to rapidly achieve and maintain pseudo-steady state drug concentrations in the plasma or at the site of drug effect. Many studies have documented the prediction accuracy of TCI devices. The authors' goal was to apply linear systems theory to characterize the relation between the variability in concentrations achieved with TCI devices and the variability in concentrations after intravenous bolus injection. Methods The authors developed a mathematical model of the variability of any arbitrary method of drug delivery, based on the variability with intravenous bolus injection or the variability with an arbitrary infusion regimen. They tested the model in a simulation of 1,000 patients receiving propofol by simple bolus injection, conventional infusion, or a TCI device. The authors then examined an experimental data set for the same behavior. Results The variability of any arbitrary infusion regimen, including TCI, is bounded by the variability after bolus injection. This is observed in the simulation and experimental data sets as well. Conclusion TCI devices neither create nor eliminate biologic variability. For any drug described by linear pharmacokinetic models, no infusion regimen, including TCI, can have higher variability than that observed after bolus injection. The median performance of TCI devices should be reasonably close to the prediction of the device. However, the overall spread of the observations is an intrinsic property of the drug, not the TCI delivery system.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference37 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3