Predictability of Processed Electroencephalography Effects on the Basis of Pharmacokinetic–Pharmacodynamic Modeling during Repeated Propofol Infusions in Patients with Extradural Analgesia

Author:

Kuizenga Karel1,Proost Johannes H.2,Wierda J. Mark3,Kalkman Cor J.4

Affiliation:

1. Staff Anesthesiologist, Department of Anesthesiology, University Hospital of Groningen.

2. Associate Professor of Anesthesiology.

3. Professor of Experimental Anesthesiology, Department of Anesthesiology, University of Groningen, Groningen, The Netherlands.

4. Professor of Anesthesiology, Department of Anesthesiology, University Medical Center Utrecht, Utrecht, The Netherlands.

Abstract

Background Pharmacokinetic-pharmacodynamic (PKPD) modeling can be used to characterize the concentration-effect relation of drugs. If the concentration-effect relation of a hypnotic drug is stable over time, an effect parameter derived from the processed electroencephalographic signal may be used to control the infusion for hypnosis. Therefore, the stability of the propofol concentration-electroencephalographic effect relation over time was investigated under non-steady state conditions. Methods Three propofol infusions (25 mg x kg(-1) x h(-1) for 10 min, 22 mg x kg(-1) x h(-1) for 10 min, and 12.5 mg x kg(-1) x h(-1) for 20 min) were administered to 10 patients during extradural analgesia. Each successive infusion was started immediately after the patient had regained responsiveness after termination of the preceding infusion. Electroencephalography was recorded from bilateral prefrontal to mastoid leads. Electroencephalographic amplitude in the 11- to 15-Hz band and the Bispectral Index were used as electroencephalographic effect variables. PKPD parameters were calculated with use of parametric and nonparametric models based on electroencephalographic data and arterial propofol concentrations derived during the initial infusion, and these were used to predict electroencephalographic effect during the subsequent infusions. The predictability of the electroencephalographic effects was determined by the coefficient of determination (R2) and of the -2 log likelihood of the sequential infusions. Results The direction of electroencephalographic changes in response to the infusions was reproducible. Although PKPD parameters could be estimated well during the initial infusion (median [range] parametric R2 = 0.74 [0.56-0.95] for electroencephalographic amplitude and 0.90 [0.27-0.99] for Bispectral Index), none of the modeling techniques could predict accurately the electroencephalographic effect during subsequent infusions (R2 = 0.00 [-0.31-0.46] for electroencephalographic amplitude and 0.15 [-.46-0.57] for Bispectral Index; P < 0.01). Conclusions The relation between blood propofol concentrations and the electroencephalographic effect under non-steady state conditions is not stable over time and is too complex to be modeled by any of the applied PKPD models.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference20 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3